108 Foxridge Dr.,, Folsom,, CA (9:00 AM - September 29, 2020)

Google Maps

Front Of House Pool Spa

Equipment Pad

Equipment #1 Equipment #2 Equipment #3 Equipment #4 Equipment #5

Safety Fencing Condition: N/A $0

Safety Fence #1 Safety Fence #2
Style Location
Wrought Iron Side of home
Safety Fencing Notes
The fencing needs minor repair to self close and self latch, The fencing does not meet safety standards
Safety Fencing Additional Notes

Pool Safety & Drowning Prevention:

As of 2018 California Building Code (CBC) for Swimming Pool Safety Barriers / Enclosures Per Health & Safety Code 115922(a), the swimming pool and/or spa shall be equipped with at least two of the following seven drowning prevention safety features. Please provide a second feature. Note that a fence along the property's perimeter is not listed.

1) an enclosure that meets the requirements of Section 115923 the swimming pool or spa from the private single-family home; and isolates

(2) removable mesh fencing that meets American Society for Testing and Materials (ASTM) Specifications F2286 standards in conjunction with a gate that is self-closing and self-latching and can accommodate a key lockable device;

(3) an approved safety pool cover, as defined in subdivision (d) of Section 115921;

(4) exit alarms on a private single-family home's doors that provide direct access to the swimming pool or spa (provided on drawings);

(5) a self-closing, self-latching device with a release mechanism placed no lower than 54" above the floor on the private single-family home's doors providing direct access to the swimming pool or spa;

(6) an alarm that, when placed in a swimming pool or spa, will sound upon detection of accidental or unauthorized entrance into the water. The alarm shall meet and be independently certified to the ASTM Standards F2208 "Standard Safety Specification of Residential Pool Alarms," which includes surface motion, pressure, sonar, laser, and infrared type alarms. A swimming protection alarm feature designed for individual use, including an alarm attached to a child that sounds when the child exceeds a certain distance or becomes submerged in water, is not a qualifying drowning prevention safety feature.

(7) other means of protection, if the degree of protection afforded is equal to or greater than that afforded by any of the features listed above and has been independently verified by an approved testing laboratory as meeting standards for those features established by the ASTM or the American society of Mechanical Engineers (ASME).

NOTE: THE CURRENT GATE AT THE FRONT / SIDE ENTRY DOES NOT MEET CURRENT CODE.
TWO DEVICES I.E.; "DROWNING PREVENTION SAFETY FEATURES" WERE NOT OBSERVED.

Pool Surface Condition: Poor $2500

Surface #1 Surface #2
Estimated Gallons Surface Type
20K - 25K Gallons Plaster
Dimensions Damaged Estimated Surface Age
15' by 32' 0-10% 1-12 Months
Pool Surface Notes
There are some small areas of staining or discoloration
Pool Surface Additional Notes

Cementitious surface coatings are susceptible to chemically and pH aggressive swimming pool water or to any chemical that is capable of deteriorating the cementitious materials of a surface coating.
Swimming pool water that is not in Ideal Range of acceptable tolerance (or “balanced”) as in accordance with the ANSI/APSP Standards is considered to be detrimental to cementitious surface coatings.
Depending on the direction of the imbalance a coating can either be stained or etched. Often, both staining and etching are exhibited on the surface of a coating as the pool water fluctuates from one extreme to the other.
There are visible signs of salt crystallization, surface efflorescence, or cracks that are emitting efflorescence or salt deposits which are common to a coating in contact with a positive saturation index (+ LSI), or “scaling” condition.
If the water is capable of leaching cement compounds from within the surface coating, then that water is in a negative saturation index (LSI), or "aggressive" condition.
If care is not taken to ensure that the water of a swimming pool is kept in an Ideal Range that is considered by ANSI/APSP to be balanced, and further that a sufficient amount of carbonate alkalinity buffer is constantly present, then the cementitious surface coating should be considered susceptible to damage from that water and deterioration may result.
Water-soluble salts, acids, or ions such as sulfates, chlorides, and carbonates, can be transported into a cementitious surface coating and react with the cementitious compounds. The resulting chemical reaction between the cementitious compounds and these salts, acids, or ions, in the presence of water, can cause deterioration to the coating. Acidic water aggressively attacks and dissolves cementitious surface materials.
Water that is low in hardness, or soft water, can cause leaching of certain compounds of the cement, especially calcium hydroxide.
For more information about the National Plastering Council's re-plastering recommendations please go to their website: https://www.npconline.org

NOTE: It appears that sometime in the past that chlorine tabs settled on the pool bottom and caused damage to the plaster.

Tile Condition: Good$

Tile #1 Tile #2
Water Line Tile Linear Footage Tile Water Level Tile Linear Footage
Less than 110 Linear Feet Ideal 1
Tile Type Calcium Build-Up Loose or missing tile?
Ceramic N/A or none
Mastic Repair
Additional Mastic Repairs
Additional Tile Notes

STATEMENT TILE REMODELING / REPLACEMENTS;

The adherence of tile or veneer products being applied during the re-tiling process of an existing swimming pool / spa and or water feature are subject to the status of the gunite shell's existing conditions. These conditions are unknown and outside the awareness of the current costs evaluations. Unknown conditions may exist that involve the effects of water saturation / penetration deterioration to the Bond Beam and or surfaces that are designated to have topical products reapplied. Repairs and remedy of such conditions are not part of any estimated costs assessments as they cannot be known until forensic investigation determines whether or not these will affect the re-applying process of the topical applications.
Therefore, until removal and discovery is performed of the existing underneath conditions, we cannot fully confirm that the intended work scope will not expand beyond the scope that’s been estimated. If this becomes a requirement an estimate will be submitted for approval prior to commencing with the additional repairs.

Water Quality Condition: Poor $130

Water Picture #1 Water Picture #2
pH Level Free Chlorine Total Chlorine Cyanuric Alkalinity Calcium
7.2 - 7.6 (Slightly High) 1 (Low) 1 (Low) 50 - 100 (Ideal) 45 - 70 (Ideal) 250 - 400 (Ideal)
pH Level Details Free Chlorine Details Total Chlorine Details Cyanuric Acid Details Alkalinity Notes Calcium Notes
Algae present? Foliage found in water? Water loss present?
An enzyme treatment would reduce dissolved organics additionally through enzyme breakdown and oxidization ($65), An enzyme treatment would reduce dissolved organics additionally through enzyme breakdown and oxidization ($65) No
Additional Water Quality Notes

Skimmer & Main Drain Circulation: Poor $65

Drain #1 Drain #2 Skimmer #1 Skimmer #2
Water Flow Through Skimmer Water Flow Through Main Drain Skimmer Float Valve
Poor 1
Pool Skimmer QTY Spa Skimmer QTY Pool Main Drain QTY Spa Main Drain QTY
1 1
VGBA Compliant Drain Covers
Skimmer & Main Drain Details
The first skimmer is in *working* condition however it is missing its skimmer *float valve o-ring* ($65)

Skimmer & Main Drain Additional Notes

Virginia Graeme Baker Pool and Spa Safety Act Information

On December 19, 2008 the Federal Virginia Graeme Baker Pool and Spa Safety Act (VGBA) became effective. The VGBA requires all pool drain covers manufactured or sold in the United States to comply with new entrapment standards. VGBA also requires owners of all new and existing public swimming pool and spa suction outlet systems to install safety equipment, including ASME/ANSI A112.19.8 certified suction outlets and covers, designed to prevent entrapment.

Currently the pool’s drain cover devices do not meet the safety requirements and should be replaced when the pool is replastered.

Bottom Cleaner Condition: Damaged, some major parts need to be replaced ($205) $455

Cleaner #1 Cleaner #2
Bottom Cleaner Brand Bottom Cleaner Model
Polaris Polair
Bottom Cleaner Additional Notes

Bottom Cleaner's hose is leaking and causing the cleaner to not function correctly. Repairs needed.

Bottom Cleaner Additional Repairs
250

Auto-Fill Condition: Good ($10)$10

Autofill #1 Autofill #2
Pool Auto-Fill Spa Auto-Fill Auto-Fill Style Fill Speed
Yes No Float Slow
Auto-Fill Additional Notes

Pool Light Condition: $575

Pool Light #1 Pool Light #2
Pool Light Type Distance From Electrical
Incandescent Bulb
Pool Light Notes
Water Present inside light lens ($575+)

NEC 680.23 Underwater Luminaires.
(A) General.

(2) Transformers. Transformers for underwater luminaires shall be an isolated winding type with a grounded metal barrier between the primary and secondary windings, and shall be listed for the purpose.
(3) GFCI Protection. Branch circuits supplying underwater luminaires that operate at more than 15V shall be GFCI protected. Figure 680-15 un680-15 680-23A3.cdr
(4) Voltage Limitation. Listed underwater luminaires shall not operate on circuits over 150V.
(5) Wall-Mounted Luminaires. Listed underwater luminaires shall be installed so that the top of the luminaire lens is at least 18 in. below the normal water level.
Author’s Comment: The 18 in. requirement is to reduce the likelihood that a person hanging over the side will have their chest cavity in line with the luminaire.

Spa Light Condition: Fair$25

Spa Light #1 Spa Light #2
Spa Light Notes
Water Present inside light lens.
Spa Light Additional Notes

NEC 680.23 Underwater Luminaires.
(A) General.

(2) Transformers. Transformers for underwater luminaires shall be an isolated winding type with a grounded metal barrier between the primary and secondary windings, and shall be listed for the purpose.
(3) GFCI Protection. Branch circuits supplying underwater luminaires that operate at more than 15V shall be GFCI protected. Figure 680-15 un680-15 680-23A3.cdr
(4) Voltage Limitation. Listed underwater luminaires shall not operate on circuits over 150V.
(5) Wall-Mounted Luminaires. Listed underwater luminaires shall be installed so that the top of the luminaire lens is at least 18 in. below the normal water level.
Author’s Comment: The 18 in. requirement is to reduce the likelihood that a person hanging over the side will have their chest cavity in line with the luminary.

Equipment Pad


Filter Condition: Poor (High Filter Pressure - Low Water Qaulity - Filter Internal Replacment $150+) $250

Filter #1 Filter #2
Filter Brand Filter Model
Hayward
Filter Notes
High Pressure - Indicating low flow, or distressed flow, with extremely high energy consumption. Recommend element replacement soon 1 - 8 weeks ($150-450)
Filter Additional Notes

Filter shows evidence of the seal leaking.

Filter Pump Condition: Good$

Filter Pump #1 Filter Pump #2
Filter Pump Brand Filter Pump Model Horsepower
Sta-Rite Variable Speed 1.5 - 3.1hp
Filter Pump Condition
The bonding wire is connected and secure
Filter Pump Notes
Great, the filter pump is in great working condition; The motor is cool, the bonding wire is secured, the pump basket is free of chips and or cannot allow larger debris to bypass, the pump lid o-ring is secure with little to no air in the pump basket during operation.
Filter Pump Additional Notes
Filter Pump Additional Repairs

Booster Pump Condition: Poor (Recommend Hose Replacement / Connection Fittings) $210$210

Booster Pump #1 Booster Pump #2
Booster Pump Brand Booster Pump Model Horsepower
Hayward, Unlabeled Pump
Booster Pump Additional Notes

Spa Jet Pump Condition: Good$

Spa Jet Pump #1 Spa Jet Pump #2
Spa Jet Brand Spa Jet Model Horsepower
Hayward
Spa Jet Additional Notes

Waterfall Pump Condition: N/A$

Waterfall Pump #1 Waterfall Pump #2
Waterfall Pump Brand Waterfall Pump Model Horsepower
Waterfall Pump Additional Notes

Auxiliary Pump A Condition: Damaged (Needs Attention)$800

Auxiliary Pump A #1 Auxiliary Pump A #2
Auxiliary Pump A Brand Auxiliary Pump A Model Horsepower
Hayward, Unlabeled Pump
Auxiliary Pump A Additional Notes

Note: Pump just hummed when power was turned on

Auxiliary Pump B Condition: N/A $

Auxiliary B #1 Auxiliary B #2
Auxiliary Pump B Brand Auxiliary Pump B Model Horsepower
Auxiliary Pump B Additional Notes

Heater Condition: Damaged (Needs Attention) $3000

Heater #1 Heater #2
Heater Model Heater Brand
Hayward 400-Btu
Heater Additional Notes

Note: Heater did not power on when activated through the controller.

Equipment Control System


Board & Timer Condition: Poor$4000

Board/Timer #1 Board/Timer #2
GFCI Compliant
Yes - The plug and or breaker are connected to the pool light and test and reset.
Board & Timer Additional Notes

Note: The LX3600 is an acquainted control system and some buttons show excessive wear. Replacement should be considered (opinion) whereas automation could be upgraded and the operational functionalities of the equipment could be optimized.

Auxiliary Timer Condition: N/A $

Auxiliary Timer #1 Auxiliary Timer #2
Auxiliary Timer Additional Notes

Salt Control Systems Condition: Poor$

Salt Control #1 Salt Control #2
Salt System Power Detect Salt Flow Detect Salt Presence Low Salt
No No No
Salt Control System Additional Notes

Valves & Fittings Condition: Poor$

Overall Details

Due for maintenance, medium equipment pad, Required every 10-15 years, all valving must be opened, cleaned, lubricated, and re sealed to ensure longevity of equipment.
No, the equipment pad is not UV protected by a UV protectant paint, recommend painting this pad to ensure long PVC piping life as well as certain equipment, The equipment appears to be in direct sunlight a large portion of the day. By simply covering the equipment with a UV mesh shade ($25-55 on Amazon + Installation) you will see approx 3x equipment life and 3x less equipment breakdown. This is recommended here.
Condition
Poor
Notes

NOTE: The pool concrete decking is sloping toward the house without any deck drainage system being able to collect the surface flow and carry it away. This condition exponentially increases the likelihood that moisture will penetrate the stucco and cause the wood framing to become saturated during peak storm periods.

RECOMMENDATION: This drainage condition should be corrected and an inspection of the home's crawl space should investigate if any water damage has been inured.

Condition
Poor
Notes

NOTE: There is overhead lighting system that's running above the pool. This was not inspected during the pool because it's running off of an electrical outlet on the home.

RECOMMENDATION: Have a certified Home Inspector investigate this lighting circuit to make sure that the installation meets current Electrical Code standards.

Condition
Poor
Notes

NOTE: The roof downspout drains on to the Equipment Pad and this is not a good idea because of excessive water drenching the pool pump motors, heater, control system, etc.

RECOMMENDATION: Divert the drainage water that is discharged from the down spout away from the Equipment Pad.

Condition
Poor
Notes

NOTE: Sub-panels and main panels alike have specific rules that need to be followed according to the National Electrical Code (NEC). All electrical panels must have a minimum of 36 inches of clearance in front of the panel, 30 inches of clearance across the face of the panel, and a minimum of 78 inches above the floor.

Condition
N/A
Notes

Estimated pool repair costs based on typical seasonal construction pricing.(seasonal pricing changes $12020Est. Totals


Edit
 

Comments are closed.



Looking for something?

Use the form below to search the site:

Still not finding what you're looking for? Drop a comment on a post or contact us so we can
take care of it!

Pool Questions ? Call Us!

Do you need some swimming pool assistance? Maybe just a few questions answered ? Well give us a call, we are only a phone call away.

Sometimes you just need a second, qualified opinion.

Office: (916) 467-8038

Mobile: (916) 905-5818

Sacramento Pool Inspections & Service

We provide Weekly Pool & Spa Service, Pool Inspections, Pool Repairs, & Pool Tile Cleaning around the Sacramento Area, CA and the surrounding communities.

Swimming Pool Inspections & Service | (916) 905-5818