Expert Level Pool Inspections
Print Friendly Edit

5547 Cabrillo Way, Rocklin, CA (11:00 AM - July 29, 2020)

Google Maps

Front Of House Pool Spa

Equipment Pad

Equipment #1 Equipment #2 Equipment #3 Equipment #4 Equipment #5

Safety Fencing Condition: Damaged (Needs Attention) $

Safety Fence #1 Safety Fence #2
Style Location
Wrought Iron Side of home, W.I. Fence @ Rear P.L.
Safety Fencing Notes
Access was through home, The fencing does not meet safety standards
Safety Fencing Additional Notes

Pool Safety & Drowning Prevention:

As of 2018 California Building Code (CBC) for Swimming Pool Safety Barriers / Enclosures Per Health & Safety Code 115922(a), the swimming pool and/or spa shall be equipped with at least two of the following seven drowning prevention safety features. Please provide a second feature. Note that a fence along the property's perimeter is not listed.

1) an enclosure that meets the requirements of Section 115923 the swimming pool or spa from the private single-family home; and isolates

(2) removable mesh fencing that meets American Society for Testing and Materials (ASTM) Specifications F2286 standards in conjunction with a gate that is self-closing and self-latching and can accommodate a key lockable device;

(3) an approved safety pool cover, as defined in subdivision (d) of Section 115921;

(4) exit alarms on a private single-family home's doors that provide direct access to the swimming pool or spa (provided on drawings);

(5) a self-closing, self-latching device with a release mechanism placed no lower than 54" above the floor on the private single-family home's doors providing direct access to the swimming pool or spa;

(6) an alarm that, when placed in a swimming pool or spa, will sound upon detection of accidental or unauthorized entrance into the water. The alarm shall meet and be independently certified to the ASTM Standards F2208 "Standard Safety Specification of Residential Pool Alarms," which includes surface motion, pressure, sonar, laser, and infrared type alarms. A swimming protection alarm feature designed for individual use, including an alarm attached to a child that sounds when the child exceeds a certain distance or becomes submerged in water, is not a qualifying drowning prevention safety feature.

(7) other means of protection, if the degree of protection afforded is equal to or greater than that afforded by any of the features listed above and has been independently verified by an approved testing laboratory as meeting standards for those features established by the ASTM or the American society of Mechanical Engineers (ASME).

NOTE: THERE ARE NO ACCESS GATES, ENTRY WAS THROUGH THE HOUSE. ENTRY AT GARAGE DOOR DOES NOT MEET CURRENT CODE.
TWO DEVICES I.E.; "DROWNING PREVENTION SAFETY FEATURES" WERE NOT OBSERVED.

Pool Surface Condition: Fair (1-72 Months) $5500

Surface #1 Surface #2
Estimated Gallons Surface Type
15K - 20K Gallons Plaster
Dimensions Damaged Estimated Surface Age
16' by 30' 0-10% 1-12 Months
Pool Surface Notes
There are large areas of staining and discoloration, The surface is slightly abrasive and not as smooth or as new and will allow more organic matter to grow as a result of the slightly abrasive surface, The pool surface has discoloration throughout due to improper water balance over time
Pool Surface Additional Notes

Plaster and Chemical Attack:

Cementitious surface coatings are susceptible to chemically and pH aggressive swimming pool water or to any chemical that is capable of deteriorating the cementitious materials of a surface coating.

Swimming pool water that is not in Ideal Range of acceptable tolerance (or “balanced”) as in accordance with the ANSI/APSP Standards is considered to be detrimental to cementitious surface coatings.

Depending on the direction of the imbalance a coating can either be stained or etched. Often, both staining and etching are exhibited on the surface of a coating as the pool water fluctuates from one extreme to the other.

There are visible signs of salt crystallization, surface efflorescence, or cracks that are emitting efflorescence or salt deposits which are common to a coating in contact with a positive saturation index (+ LSI), or “scaling” condition.

If the water is capable of leaching cement compounds from within the surface coating, then that water is in a negative saturation index (LSI), or "aggressive" condition.

If care is not taken to ensure that the water of a swimming pool is kept in an Ideal Range that is considered by ANSI/APSP to be balanced, and further that a sufficient amount of carbonate alkalinity buffer is constantly present, then the cementitious surface coating should be considered susceptible to damage from that water and deterioration may result.

Water-soluble salts, acids, or ions such as sulfates, chlorides, and carbonates, can be transported into a cementitious surface coating and react with the cementitious compounds. The resulting chemical reaction between the cementitious compounds and these salts, acids, or ions, in the presence of water, can cause deterioration to the coating. Acidic water aggressively attacks and dissolves cementitious surface materials.

Water that is low in hardness, or soft water, can cause leaching of certain compounds of the cement, especially calcium hydroxide.

For more information about the National Plastering Council's re-plastering recommendations please go to their website: https://www.npconline.org

Tile Condition: Other$1500

Tile #1 Tile #2
Water Line Tile Linear Footage Tile Water Level Tile Linear Footage
Less than 110 Linear Feet Low
Tile Type Calcium Build-Up Loose or missing tile?
Ceramic Medium Build Up ($550)
Mastic Repair
Estimated Repairs ($555)
Additional Mastic Repairs

STATEMENT TILE REMODELING / REPLACEMENTS;

The adherence of tile or veneer products being applied during the re-tiling process of an existing swimming pool / spa and or water feature are subject to the status of the gunite shell's existing conditions. These conditions are unknown and outside the awareness of the current costs evaluations. Unknown conditions may exist that involve the effects of water saturation / penetration deterioration to the Bond Beam and or surfaces that are designated to have topical products reapplied. Repairs and remedy of such conditions are not part of any estimated costs assessments as they cannot be known until forensic investigation determines whether or not these will affect the re-applying process of the topical applications.

Therefore, until removal and discovery is performed of the existing underneath conditions, we cannot fully confirm that the intended work scope will not expand beyond the scope that’s been estimated. If this becomes a requirement an estimate will be submitted for approval prior to commencing with the additional repairs.

Additional Tile Notes

The black plastic water stop material that is located between the top of the tile and the bottom of the concrete coping edge is deteriorated and separating from the edge.

Water Quality Condition: Good $285

Water Picture #1 Water Picture #2
pH Level Free Chlorine Total Chlorine Cyanuric Alkalinity Calcium
7.2 - 7.6 (Slightly High) 2 - 5 (Ideal) 2 - 5 (Ideal) 100 - 120 (Slightly High) 140+ (Extremely High) 650+ (High)
pH Level Details Free Chlorine Details Total Chlorine Details Cyanuric Acid Details Alkalinity Notes Calcium Notes
Algae present? Foliage found in water? Water loss present?
No
Additional Water Quality Notes

The water level was slightly low and the Autofill Device was turned off. When turned on the "packing grand" around the valve stem was leaking. Need attention.

Skimmer & Main Drain Circulation: N/A $65

Drain #1 Drain #2 Skimmer #1 Skimmer #2
Water Flow Through Skimmer Water Flow Through Main Drain Skimmer Float Valve
N/A 1
Pool Skimmer QTY Spa Skimmer QTY Pool Main Drain QTY Spa Main Drain QTY
1 N/A 1 N/A
VGBA Compliant Drain Covers
Skimmer & Main Drain Details
The first skimmer is in *working* condition however it is missing its skimmer *float valve o-ring* ($65)

Skimmer & Main Drain Additional Notes

Virginia Graeme Baker Pool and Spa Safety Act Information

On December 19, 2008 the Federal Virginia Graeme Baker Pool and Spa Safety Act (VGBA) became effective. The VGBA requires all pool drain covers manufactured or sold in the United States to comply with new entrapment standards. VGBA also requires owners of all new and existing public swimming pool and spa suction outlet systems to install safety equipment, including ASME/ANSI A112.19.8 certified suction outlets and covers, designed to prevent entrapment.

Currently the pool’s drain cover devices do not meet the safety requirements and should be replaced when the pool is replastered.

Bottom Cleaner Condition: Damaged, some major parts need to be replaced ($205) $205

Cleaner #1 Cleaner #2
Bottom Cleaner Brand Bottom Cleaner Model
Polaris
Bottom Cleaner Additional Notes
Bottom Cleaner Additional Repairs

Auto-Fill Condition: Poor ($125)$150

Autofill #1 Autofill #2
Pool Auto-Fill Spa Auto-Fill Auto-Fill Style Fill Speed
Yes Float Slow
Auto-Fill Additional Notes

Pool Light Condition: Damaged$925

Pool Light #1 Pool Light #2
Pool Light Type Distance From Electrical
Incandescent Bulb 50' or less
Pool Light Notes
Water Present inside light lens ($575+)

NEC 680.23 Underwater Luminaires.
(A) General.

THE GFCI FOR THE LIGHT WAS TRIPPED IN THE OFF POSITION AND THE BUTTON IN AT THE PANEL DID NOT FUNCTION.
(2) Transformers. Transformers for underwater luminaires shall be an isolated winding type with a grounded metal barrier between the primary and secondary windings, and shall be listed for the purpose.
(3) GFCI Protection. Branch circuits supplying underwater luminaires that operate at more than 15V shall be GFCI protected. Figure 680-15 un680-15 680-23A3.cdr
(4) Voltage Limitation. Listed underwater luminaires shall not operate on circuits over 150V.
(5) Wall-Mounted Luminaires. Listed underwater luminaires shall be installed so that the top of the luminaire lens is at least 18 in. below the normal water level.
Author’s Comment: The 18 in. requirement is to reduce the likelihood that a person hanging over the side will have their chest cavity in line with the luminaire.

Spa Light Condition: $

Spa Light #1 Spa Light #2
Spa Light Notes
Spa Light Additional Notes

Equipment Pad


Filter Condition: Fair (Normal to High Filter Pressure - Filter Cleaning Treatment Recommended $55) $450

Filter #1 Filter #2
Filter Brand Filter Model
Hayward SWIMCLEAR CARTRIDGE
Filter Notes
Normal to High Filter Pressure - Indicating a filter cleaning ($85) is necessary to identify filter element quality of life, if elements were recently cleaned this is indicating element replacement is needed in the next 1 - 24 months ($150-450)
Filter Additional Notes

Filter Pump Condition: Good$

Filter Pump #1 Filter Pump #2
Filter Pump Brand Filter Pump Model Horsepower
Hayward 1.25HP - 1,50HP
Filter Pump Condition
The bonding wire is connected and secure
Filter Pump Notes
Good, the filter pump is in good working condition; The motor is warm or slightly hot, some air in the pump basket, motor is hot to the touch, recommend upgrading the status of this pump by; cleaning, lubricating, and resealing all pump suction and return side fitting o-rings.
Filter Pump Additional Notes
Filter Pump Additional Repairs

Booster Pump Condition: $450

Booster Pump #1 Booster Pump #2
Booster Pump Brand Booster Pump Model Horsepower
Sta-Rite ≤ 0.99HP
Booster Pump Additional Notes

The Pool Cleaner's Booster pump has a noisy bearing.

Spa Jet Pump Condition: N/A$

Spa Jet Pump #1 Spa Jet Pump #2
Spa Jet Brand Spa Jet Model Horsepower
Spa Jet Additional Notes

Waterfall Pump Condition: N/A$

Waterfall Pump #1 Waterfall Pump #2
Waterfall Pump Brand Waterfall Pump Model Horsepower
Waterfall Pump Additional Notes

The Waterfall was activated by manually turning a return line valve.

The Rock running along the upper Bond Beam has settled and separated and the Rock that is adjacent to the upper sun deck shows signs of deck settlement.

OPINION: This may be indicative of water getting under the deck while running the Waterfall over time.

Auxiliary Pump A Condition: N/A$

Auxiliary Pump A #1 Auxiliary Pump A #2
Auxiliary Pump A Brand Auxiliary Pump A Model Horsepower
Auxiliary Pump A Additional Notes

Auxiliary Pump B Condition: N/A $

Auxiliary B #1 Auxiliary B #2
Auxiliary Pump B Brand Auxiliary Pump B Model Horsepower
Auxiliary Pump B Additional Notes

Heater Condition: N/A $

Heater #1 Heater #2
Heater Model Heater Brand
Heater Additional Notes

Equipment Control System


Board & Timer Condition: Poor$

Board/Timer #1 Board/Timer #2
GFCI Compliant
No - Older GFI standard, tests, and resets the pool and or spa light. Recommend upgrading to GFCI standard for safety ($125)
Board & Timer Additional Notes

According to NEC Section 680 there needs to be a clear 3'-0" distance in front of the Sub-Panel. The Sub-Panel is not code compliant. An access door should be installed that will meet the code requirements.

Auxiliary Timer Condition: N/A $

Auxiliary Timer #1 Auxiliary Timer #2
Auxiliary Timer Additional Notes

The Solar heat valve actuator was operational at the time of this inspection but, the solar panels on the roof could not be observed. The Solar controller activated the valve but again the overall system could not be evaluated.

Salt Control Systems Condition: Poor$

Salt Control #1 Salt Control #2
Salt System Power Detect Salt Flow Detect Salt Presence Low Salt
Yes No Yes Yes
Salt Control System Additional Notes

OPINION: It appears that the salt system is in need of repairs.

Valves & Fittings Condition: Poor$

Overall Details

NOTE: A crack on the upper deck shows signs of an attempt to repair it. OPINION: This crack may have something to do with the upper deck settling and the Waterfall Rock separation.


Due for maintenance, small equipment pad, Required every 10-15 years, all valving must be opened, cleaned, lubricated, and re sealed to ensure longevity of equipment.
Yes, the equipment pad is UV protected by a UV protectant paint, recommend painting this pad to ensure long PVC piping life as well as certain equipment
Condition
N/A
Notes
Condition
N/A
Notes
Condition
N/A
Notes
Condition
N/A
Notes
Condition
N/A
Notes

Estimated pool repair costs based on typical seasonal construction pricing.(seasonal pricing changes $8605Est. Totals


Edit
 

Comments are closed.



Looking for something?

Use the form below to search the site:

Still not finding what you're looking for? Drop a comment on a post or contact us so we can
take care of it!

Pool Questions ? Call Us!

Do you need some swimming pool assistance? Maybe just a few questions answered ? Well give us a call, we are only a phone call away.

Sometimes you just need a second, qualified opinion.

Office: (916) 467-8038

Mobile: (916) 905-5818

Sacramento Pool Inspections & Service

We provide Weekly Pool & Spa Service, Pool Inspections, Pool Repairs, & Pool Tile Cleaning around the Sacramento Area, CA and the surrounding communities.

Swimming Pool Inspections & Service | (916) 905-5818