The skimmer #1 appears to be partially eroded on the intake opening from high flow damaged, not to mention the VERY high chlorine levels either in the pool or chlorine cookies in the skimmer basket. This might be why there is leak repair / putty repair present on both opening as well. If there are leaks present on this skimmer it may require the skimmer to be short term repaired again ($350) with putty or long term completely replaced ($2500). I would side with the second option to resolve any issue present, for a permanent repair.
In the mean time on when deciding which repair would be best in the future I recommend replacement skimmer internals for optimal use ($170).
The in floor cleaning system canister /next to skimmer also has some unusual issues present specifically on the return? port. Noting there is some type of possible duct tape on the inside of the opening. This is not ideal or usual and should be resolved / investigated to resolve any issue IF any.
The NEWER main drain covers in the pool appear to be in ideal condition, and VGBA complaint COVERS present, however there needs to be a greater distance from the pipe inlet to the cover surface to be truly VGBA complaint 1.5x the diameter of the pipe + cannot exceed 6 feet velocity. I do not feel this falls under that guideline even when the in floor cleaning system is active as a suction port. This could be possible if typing in the suction line of the waterfall pump ($450).
Also note it appears all covers except one cover has been replaced of the group as one looks much older than the others, for an unknown reason why all weren't replaced. If I had to guess the older covers became brittle and had to be replaced in part due to the high chlorine.
The main drain of the in floor cleaning canister is newer than 7 years but equally damaged from high chlorine content.
|