1850 Maple Glen Road, , Sacramento, CA (10:00 AM - May 20, 2020)

Google Maps

Front Of House Pool Spa

Equipment Pad

Equipment #1 Equipment #2 Equipment #3 Equipment #4 Equipment #5

Safety Fencing Condition: Poor $0

Safety Fence #1 Safety Fence #2
Style Location
Wooden, Wrought Iron Around pool
Safety Fencing Notes
The fencing does not meet safety standards
Safety Fencing Additional Notes

Pool Safety & Drowning Prevention:

As of 2018 California Building Code (CBC) for Swimming Pool Safety Barriers / Enclosures Per Health & Safety Code 115922(a), the swimming pool and/or spa shall be equipped with at least two of the following seven drowning prevention safety features. Please provide a second feature. Note that a fence along the property's perimeter is not listed.

1) an enclosure that meets the requirements of Section 115923 the swimming pool or spa from the private single-family home; and isolates

(2) removable mesh fencing that meets American Society for Testing and Materials (ASTM) Specifications F2286 standards in conjunction with a gate that is self-closing and self-latching and can accommodate a key lockable device;

(3) an approved safety pool cover, as defined in subdivision (d) of Section 115921;

(4) exit alarms on a private single-family home's doors that provide direct access to the swimming pool or spa (provided on drawings);

(5) a self-closing, self-latching device with a release mechanism placed no lower than 54" above the floor on the private single-family home's doors providing direct access to the swimming pool or spa;

(6) an alarm that, when placed in a swimming pool or spa, will sound upon detection of accidental or unauthorized entrance into the water. The alarm shall meet and be independently certified to the ASTM Standards F2208 "Standard Safety Specification of Residential Pool Alarms," which includes surface motion, pressure, sonar, laser, and infrared type alarms. A swimming protection alarm feature designed for individual use, including an alarm attached to a child that sounds when the child exceeds a certain distance or becomes submerged in water, is not a qualifying drowning prevention safety feature.

(7) other means of protection, if the degree of protection afforded is equal to or greater than that afforded by any of the features listed above and has been independently verified by an approved testing laboratory as meeting standards for those features established by the ASTM or the American society of Mechanical Engineers (ASME).

NOTE: THE CURRENT GATE AT THE FRONT / SIDE ENTRY DOES NOT MEET CURRENT CODE.
TWO DEVICES I.E.; "DROWNING PREVENTION SAFETY FEATURES" WERE NOT OBSERVED.

Pool Surface Condition: Poor $8500

Surface #1 Surface #2
Estimated Gallons Surface Type
>25K Gallons Plaster
Dimensions Damaged Estimated Surface Age
44' by 19' 50-100% 12-48 Months
Pool Surface Notes
The pool surface has discoloration throughout due to improper water balance over time, The pool surface has heavy wear, pitting, and or missing surface areas
Pool Surface Additional Notes

Plaster and Chemical Attack:

Cementitious surface coatings are susceptible to chemically and pH aggressive swimming pool water or to any chemical that is capable of deteriorating the cementitious materials of a surface coating.

Swimming pool water that is not in Ideal Range of acceptable tolerance (or “balanced”) as in accordance with the ANSI/APSP Standards is considered to be detrimental to cementitious surface coatings.

Depending on the direction of the imbalance a coating can either be stained or etched. Often, both staining and etching are exhibited on the surface of a coating as the pool water fluctuates from one extreme to the other.

There are visible signs of salt crystallization, surface efflorescence, or cracks that are emitting efflorescence or salt deposits which are common to a coating in contact with a positive saturation index (+ LSI), or “scaling” condition.

If the water is capable of leaching cement compounds from within the surface coating, then that water is in a negative saturation index (LSI), or "aggressive" condition.

If care is not taken to ensure that the water of a swimming pool is kept in an Ideal Range that is considered by ANSI/APSP to be balanced, and further that a sufficient amount of carbonate alkalinity buffer is constantly present, then the cementitious surface coating should be considered susceptible to damage from that water and deterioration may result.

Water-soluble salts, acids, or ions such as sulfates, chlorides, and carbonates, can be transported into a cementitious surface coating and react with the cementitious compounds. The resulting chemical reaction between the cementitious compounds and these salts, acids, or ions, in the presence of water, can cause deterioration to the coating. Acidic water aggressively attacks and dissolves cementitious surface materials.

Water that is low in hardness, or soft water, can cause leaching of certain compounds of the cement, especially calcium hydroxide.

For more information about the National Plastering Council's re-plastering recommendations please go to their website: https://www.npconline.org

Tile Condition: Good$

Tile #1 Tile #2
Water Line Tile Linear Footage Tile Water Level Tile Linear Footage
Less than 150 Linear Feet Low
Tile Type Calcium Build-Up Loose or missing tile?
Ceramic N/A or none
Mastic Repair
Other
Additional Mastic Repairs

There are decorative plastic strips that are placed at the concrete decking joints. Over time due to UV, chemical and foot traffic exposure they will decay and breakdown. There are some locations where these strips are showing signs of decay.

Additionally, concrete swimming pool decking should not exceed an 8' x 8' spanning of distance between control jointing. The purpose of these joints are to provide an anticipated weakness in the surface at a designated location. As concrete is most likely to crack, control joints can enhance the likelihood for where the cracking shall occur. There are several areas that exceed the spanning distance for this concrete engineering guideline and as a result the deck has some cracking and settling that is indicative of failing to provide adequate jointing and or sub-grade preparations / compaction.

Although it is not unusual to see this and especially around a pool of this era.

Additional Tile Notes

Water Quality Condition: Poor $235

Water Picture #1 Water Picture #2
pH Level Free Chlorine Total Chlorine Cyanuric Alkalinity Calcium
6.8 - 7.2 (Ideal) 2 - 5 (Ideal) 5 - 10 (Slightly High) 0 - 20 (Very Low) 70 - 100 (Slightly High) 250 - 400 (Ideal)
pH Level Details Free Chlorine Details Total Chlorine Details Cyanuric Acid Details Alkalinity Notes Calcium Notes
Algae present? Foliage found in water? Water loss present?
Yes - Recommend Phosphate Treatment Yes
Additional Water Quality Notes

Skimmer & Main Drain Circulation: Good $380

Drain #1 Drain #2 Skimmer #1 Skimmer #2
Water Flow Through Skimmer Water Flow Through Main Drain Skimmer Float Valve
Good 2
Pool Skimmer QTY Spa Skimmer QTY Pool Main Drain QTY Spa Main Drain QTY
2 N/A 1 1
VGBA Compliant Drain Covers
Skimmer & Main Drain Details
The first skimmer is in *working* condition however it is missing its skimmer *float valve o-ring* ($65)
The second skimmer is in *working* condition however it is missing its skimmer *float valve o-ring* ($65)
Skimmer & Main Drain Additional Notes

Virginia Graeme Baker Pool and Spa Safety Act Information

On December 19, 2008 the Federal Virginia Graeme Baker Pool and Spa Safety Act (VGBA) became effective. The VGBA requires all pool drain covers manufactured or sold in the United States to comply with new entrapment standards. VGBA also requires owners of all new and existing public swimming pool and spa suction outlet systems to install safety equipment, including ASME/ANSI A112.19.8 certified suction outlets and covers, designed to prevent entrapment.

Currently the pool’s drain cover devices do not meet the safety requirements and should be replaced when the pool is replastered.

Bottom Cleaner Condition: Fair, minimal parts needed for tune-up ($105) $105

Cleaner #1 Cleaner #2
Bottom Cleaner Brand Bottom Cleaner Model
Pentair Racer
Bottom Cleaner Additional Notes

RECOMMENDATION; Have a full service perform on the cleaner.

Bottom Cleaner Additional Repairs
250

Auto-Fill Condition: Great$

Autofill #1 Autofill #2
Pool Auto-Fill Spa Auto-Fill Auto-Fill Style Fill Speed
Yes No Manual Medium
Auto-Fill Additional Notes

The Autofill's manual valve is located some distance away from the pool located in the area of the breezeway between the garage and the main home. The valve is an Anti-siphon type and is approved by plumbing code for manual operation.

Pool Light Condition: Good$55

Pool Light #1 Pool Light #2
Pool Light Type Distance From Electrical
Incandescent Bulb 50' or less
Pool Light Notes
Light is in fair condition and I would expect this light to last another 1-5 years, recommend cleaning light fixture ($55)

NEC 680.23 Underwater Luminaires.
(A) General.

(2) Transformers. Transformers for underwater luminaires shall be an isolated winding type with a grounded metal barrier between the primary and secondary windings, and shall be listed for the purpose.
(3) GFCI Protection. Branch circuits supplying underwater luminaires that operate at more than 15V shall be GFCI protected. Figure 680-15 un680-15 680-23A3.cdr
(4) Voltage Limitation. Listed underwater luminaires shall not operate on circuits over 150V.
(5) Wall-Mounted Luminaires. Listed underwater luminaires shall be installed so that the top of the luminaire lens is at least 18 in. below the normal water level.
Author’s Comment: The 18 in. requirement is to reduce the likelihood that a person hanging over the side will have their chest cavity in line with the luminaire.

Spa Light Condition: Fair$25

Spa Light #1 Spa Light #2
Spa Light Notes
Light is in fair condition and I would expect this light to last another 1-5 years, recommend cleaning area behind light
Spa Light Additional Notes

NEC 680.23 Underwater Luminaires.
(A) General.

(2) Transformers. Transformers for underwater luminaires shall be an isolated winding type with a grounded metal barrier between the primary and secondary windings, and shall be listed for the purpose.
(3) GFCI Protection. Branch circuits supplying underwater luminaires that operate at more than 15V shall be GFCI protected. Figure 680-15 un680-15 680-23A3.cdr
(4) Voltage Limitation. Listed underwater luminaires shall not operate on circuits over 150V.
(5) Wall-Mounted Luminaires. Listed underwater luminaires shall be installed so that the top of the luminaire lens is at least 18 in. below the normal water level.
Author’s Comment: The 18 in. requirement is to reduce the likelihood that a person hanging over the side will have their chest cavity in line with the luminaire.

Equipment Pad


Filter Condition: Poor (High Filter Pressure - Low Water Qaulity - Filter Internal Replacment $150+) $850

Filter #1 Filter #2
Filter Brand Filter Model
Pentair Purex Triton FNS Plus D.E.
Filter Notes
High Pressure - Indicating low flow, or distressed flow, with extremely high energy consumption. Recommend element replacement soon 1 - 8 weeks ($150-450)
Filter Additional Notes

It was evident that diatomaceous earth (D.E.) had bypassed the filter and been deposited upon the steps and benches inside the pool at the return pipe's locations. This could be a result of having a.) cleaned the filter recently and not taken adequate precautions to rinse out the residual D.E. from the filter elements and plumbing system, b.) a situation where one or more of the elements are damaged and or c.) a situation where the filter element's laterals are not seated property in the apparatus assembly.

RECOMMENDATION; Investigate the filter's internal condition and make a determination as what maybe the issue.

Filter Pump Condition: Poor$150

Filter Pump #1 Filter Pump #2
Filter Pump Brand Filter Pump Model Horsepower
Pentair Variable Speed 1.5 - 3.1hp
Filter Pump Condition
Water leaking from the return and/ or suction sides of pump connection(s)., The bonding wire is connected and secure
Filter Pump Notes
Poor, the pool pump has significant air or is struggling to prime in its pump basket. The motor is failing making loud noise, the shaft o-ring or seal plate o-ring has failed and is leaking, and / or has hot or very hot motor.
Filter Pump Additional Notes

The pump's system's connections in several locations showed signs of some leaking when the pump was operating at the upper pump speed.

The suggestive solution is further explained in the Valves and Fittings category.

Filter Pump Additional Repairs

Booster Pump Condition: $

Booster Pump #1 Booster Pump #2
Booster Pump Brand Booster Pump Model Horsepower
Booster Pump Additional Notes

Spa Jet Pump Condition: N/A$

Spa Jet Pump #1 Spa Jet Pump #2
Spa Jet Brand Spa Jet Model Horsepower
Spa Jet Additional Notes

The spa does not utilize a "spa booster pump" for the spa jets. The spa shares a pool / spa filtration pump and the spa jets are further regulated by a valve that's located under a deck lid cover that's adjacent to the spa.

Additionally, there is not an Air Blower for the spa either. The spa's venturi jets induce air that's drawn in from the double elbow Hartford Loop standpipe at the Equipment Pad's location.


Waterfall Pump Condition: N/A$

Waterfall Pump #1 Waterfall Pump #2
Waterfall Pump Brand Waterfall Pump Model Horsepower
Waterfall Pump Additional Notes

Auxiliary Pump A Condition: N/A$

Auxiliary Pump A #1 Auxiliary Pump A #2
Auxiliary Pump A Brand Auxiliary Pump A Model Horsepower
Auxiliary Pump A Additional Notes

Auxiliary Pump B Condition: N/A $

Auxiliary B #1 Auxiliary B #2
Auxiliary Pump B Brand Auxiliary Pump B Model Horsepower
Auxiliary Pump B Additional Notes

Heater Condition: Good $

Heater #1 Heater #2
Heater Model Heater Brand
Sta-Rite 333K BTU
Heater Additional Notes

The Heater was functioning via the manual control at the heater

Equipment Control System


Board & Timer Condition: Fair$

Board/Timer #1 Board/Timer #2
GFCI Compliant
Yes - The plug and or breaker are connected to the pool light and test and reset.
Board & Timer Additional Notes

The automation / timer system functions in the manual mode and the variable speed pump is programmable but, the automation remote aspect appears to be non-operational.

Repairs could be made but evaluating its remaining longevity due its condition couldn't provide any guarantee nor warranty.

RECOMMENDATION; Consider upgrading the Automation Control System to something that can allow remote control function from a smart phone.

Auxiliary Timer Condition: N/A $

Auxiliary Timer #1 Auxiliary Timer #2
Auxiliary Timer Additional Notes

The solar function appeared to be in manual working order and at the time of the inspection no leaks were observed on the roof panels. The system required turning valves for manual operation in order to allow water to flow through the solar system.

RECOMMENDATION; Consider upgrading the Automation Control System to something that can allow remote control function from a smart phone.

Salt Control Systems Condition: N/A$

Salt Control #1 Salt Control #2
Salt System Power Detect Salt Flow Detect Salt Presence Low Salt
Salt Control System Additional Notes

Valves & Fittings Condition: Poor$1500

Overall Details

Due for maintenance, medium equipment pad, Required every 10-15 years, all valving must be opened, cleaned, lubricated, and re sealed to ensure longevity of equipment.
No, the equipment pad is not UV protected by a UV protectant paint, recommend painting this pad to ensure long PVC piping life as well as certain equipment
Condition
N/A
Notes

OPINION: The original paint on the above ground piping at the Equipment Pad's location needs to be repainted in order to provided UV protection.

Additionally, it appears that other repairs have been performed and fittings replaced that have had no paint applied after being installed.

RECOMMENDATION: Check for the sources of leaks that were observed during the high pumping flow-rate function.

Make plumbing repairs as necessary and reconfigure some aspects of the Equipment Pads plumbing system's routing that are contributing inefficiency to the flow dynamics. Service all valves and then repaint all piping.

Condition
N/A
Notes

Due to the apparent age of the Diving Board's hardware (rusty bolts) the hardware should be disassembled and investigated for the apparent metal decay, in order to see if the severity of decay may lead failure while being used.

RECOMMENDATION: Investigate the condition of the supports and replace any hardware that does not meet the Mfgr's standards for safe use.

Condition
N/A
Notes

DIVING BOARD:

Due to the inherent risk associated with using diving boards it is important to be sure to verify that the maximum rate of rise (3:1 ratio) for the pool's bottom is following the diving board's Mfgr's guidelines together with the minimum depth (8.5' depth) requirements before using this equipment.

For further information about Diving Board regulations go to; https://srsmith.com/en-us/products/residential-products/diving-boards/

Condition
N/A
Notes
Condition
N/A
Notes

Estimated pool repair costs based on typical seasonal construction pricing.(seasonal pricing changes $11745Est. Totals


Edit
 

Comments are closed.



Looking for something?

Use the form below to search the site:

Still not finding what you're looking for? Drop a comment on a post or contact us so we can
take care of it!

Pool Questions ? Call Us!

Do you need some swimming pool assistance? Maybe just a few questions answered ? Well give us a call, we are only a phone call away.

Sometimes you just need a second, qualified opinion.

Office: (916) 467-8038

Mobile: (916) 905-5818

Sacramento Pool Inspections & Service

We provide Weekly Pool & Spa Service, Pool Inspections, Pool Repairs, & Pool Tile Cleaning around the Sacramento Area, CA and the surrounding communities.

Swimming Pool Inspections & Service | (916) 905-5818