Expert Level Pool Inspections
Print Friendly Edit

406 Lexington, Folsom, CA (1:00 PM - May 5, 2020)

Google Maps

Front Of House Pool Spa

Equipment Pad

Equipment #1 Equipment #2 Equipment #3 Equipment #4 Equipment #5

Safety Fencing Condition: Poor $

Safety Fence #1 Safety Fence #2
Style Location
Wooden
Safety Fencing Notes
The fencing needs minor repair to self close and self latch, The access gate does not swing away from the pool
Safety Fencing Additional Notes

Pool Safety & Drowning Prevention:

As of 2018 California Building Code (CBC) for Swimming Pool Safety Barriers / Enclosures Per Health & Safety Code 115922(a), the swimming pool and/or spa shall be equipped with at least two of the following seven drowning prevention safety features. Please provide a second feature. Note that a fence along the property's perimeter is not listed.

1) an enclosure that meets the requirements of Section 115923 the swimming pool or spa from the private single-family home; and isolates

(2) removable mesh fencing that meets American Society for Testing and Materials (ASTM) Specifications F2286 standards in conjunction with a gate that is self-closing and self-latching and can accommodate a key lockable device;

(3) an approved safety pool cover, as defined in subdivision (d) of Section 115921;

(4) exit alarms on a private single-family home's doors that provide direct access to the swimming pool or spa (provided on drawings);

(5) a self-closing, self-latching device with a release mechanism placed no lower than 54" above the floor on the private single-family home's doors providing direct access to the swimming pool or spa;

(6) an alarm that, when placed in a swimming pool or spa, will sound upon detection of accidental or unauthorized entrance into the water. The alarm shall meet and be independently certified to the ASTM Standards F2208 "Standard Safety Specification of Residential Pool Alarms," which includes surface motion, pressure, sonar, laser, and infrared type alarms. A swimming protection alarm feature designed for individual use, including an alarm attached to a child that sounds when the child exceeds a certain distance or becomes submerged in water, is not a qualifying drowning prevention safety feature.

(7) other means of protection, if the degree of protection afforded is equal to or greater than that afforded by any of the features listed above and has been independently verified by an approved testing laboratory as meeting standards for those features established by the ASTM or the American society of Mechanical Engineers (ASME).

NOTE: THE CURRENT GATE AT THE FRONT / SIDE ENTRY DOES NOT MEET CURRENT CODE.

TWO DEVICES I.E.; "DROWNING PREVENTION SAFETY FEATURES" WERE NOT OBSERVED.

Pool Surface Condition: Good $6000

Surface #1 Surface #2
Estimated Gallons Surface Type
10K - 15K Gallons Plaster
Dimensions Damaged Estimated Surface Age
' by ' 50-100% 1-12 Months
Pool Surface Notes
The pool surface appears to have no pitting or any loose surfaces present, The pool surface has discoloration throughout due to improper water balance over time, The pool surface has heavy wear, pitting, and or missing surface areas, Recommend re-surface as soon as possible
Pool Surface Additional Notes

Plaster and Chemical Attack:

Cementitious surface coatings are susceptible to chemically and pH aggressive swimming pool water or to any chemical that is capable of deteriorating the cementitious materials of a surface coating.

Swimming pool water that is not in Ideal Range of acceptable tolerance (or “balanced”) as in accordance with the ANSI/APSP Standards is considered to be detrimental to cementitious surface coatings.

Depending on the direction of the imbalance a coating can either be stained or etched. Often, both staining and etching are exhibited on the surface of a coating as the pool water fluctuates from one extreme to the other.

There are visible signs of salt crystallization, surface efflorescence, or cracks that are emitting efflorescence or salt deposits which are common to a coating in contact with a positive saturation index (+ LSI), or “scaling” condition.

If the water is capable of leaching cement compounds from within the surface coating, then that water is in a negative saturation index (LSI), or "aggressive" condition.

If care is not taken to ensure that the water of a swimming pool is kept in an Ideal Range that is considered by ANSI/APSP to be balanced, and further that a sufficient amount of carbonate alkalinity buffer is

constantly present, then the cementitious surface coating should be considered susceptible to damage from that water and deterioration may result.

Water-soluble salts, acids, or ions such as sulfates, chlorides, and carbonates, can be transported into a cementitious surface coating and react with the cementitious compounds. The resulting chemical reaction between the cementitious compounds and these salts, acids, or ions, in the presence of water, can cause deterioration to the coating. Acidic water aggressively attacks and dissolves cementitious surface materials.

Water that is low in hardness, or soft water, can cause leaching of certain compounds of the cement, especially calcium hydroxide.

For more information about the National Plastering Council's re-plastering recommendations please go to their website: https://www.npconline.org

Tile Condition: Poor$450

Tile #1 Tile #2
Water Line Tile Linear Footage Tile Water Level Tile Linear Footage
Less than 80 Linear Feet Ideal
Tile Type Calcium Build-Up Loose or missing tile?
Ceramic N/A or none Less than 20 tiles ($450)
Mastic Repair
Additional Mastic Repairs
Additional Tile Notes

NOTE: TILE AND GROUT WAS MISSING AT THE SPA SPILLWAY. ALSO, ROCK WAS SET BELOW THE WATERLINE IN THE POOL AND COULD NOT BE DETERMINED WHETHER OR NOT THE MORTAR BETWEEN THE ROCKS WAS LEAK PROOF.

OPINION: TYPICALLY WHEN GROUT AND TILE ARE MISSING IN A POOL, IT SHOULD BE ASSUMED THAT THE MORTAR BETWEEN THE ROCKS MAY ALSO HAVE ISSUES.
AT THE TIME OF RE-PLASTERING / RE-TILING THE ROCK MORTAR SHOULD ALSO BE ADDRESSED AS NEEDED.

Water Quality Condition: Poor $

Water Picture #1 Water Picture #2
pH Level Free Chlorine Total Chlorine Cyanuric Alkalinity Calcium
6.5 - 6.8 (Low) 2 - 5 (Ideal) 2 - 5 (Ideal) 0 - 20 (Very Low) 45 - 70 (Ideal) 250 - 400 (Ideal)
pH Level Details Free Chlorine Details Total Chlorine Details Cyanuric Acid Details Alkalinity Notes Calcium Notes
Algae present? Foliage found in water? Water loss present?
No
Additional Water Quality Notes

Skimmer & Main Drain Circulation: Good $153

Drain #1 Drain #2 Skimmer #1 Skimmer #2
Water Flow Through Skimmer Water Flow Through Main Drain Skimmer Float Valve
Good 1
Pool Skimmer QTY Spa Skimmer QTY Pool Main Drain QTY Spa Main Drain QTY
1 N/A 1 1
VGBA Compliant Drain Covers
No / Could Not Determine / Recommend VGBA Compliant Cover ($88)
Skimmer & Main Drain Details
The first skimmer is in *working* condition however it is missing its skimmer *float valve o-ring* ($65)

Skimmer & Main Drain Additional Notes

Virginia Graeme Baker Pool and Spa Safety Act Information

On December 19, 2008 the Federal Virginia Graeme Baker Pool and Spa Safety Act (VGBA) became effective. The VGBA requires all pool drain covers manufactured or sold in the United States to comply with new entrapment standards. VGBA also requires owners of all new and existing public swimming pool and spa suction outlet systems to install safety equipment, including ASME/ANSI A112.19.8 certified suction outlets and covers, designed to prevent entrapment.

Currently the pool’s drain cover devices do not meet the safety requirements and should be replaced when the pool is replastered.

Bottom Cleaner Condition: Good $25

Cleaner #1 Cleaner #2
Bottom Cleaner Brand Bottom Cleaner Model
Polaris SUCTUION SIDE
Bottom Cleaner Additional Notes

THE POOL CLEANER WAS FUNCTIONING BUT SHOULD BE SERVICED.

Bottom Cleaner Additional Repairs

Auto-Fill Condition: Good ($10)$

Autofill #1 Autofill #2
Pool Auto-Fill Spa Auto-Fill Auto-Fill Style Fill Speed
Yes No Manual Slow
Auto-Fill Additional Notes

Pool Light Condition: Damaged$750

Pool Light #1 Pool Light #2
Pool Light Type Distance From Electrical
Pool Light Notes

NOTE: OWNER INDICATED THAT THE POOL LIGHT / SPA LIGHT DO NOT OPERATE. DURING THE INSPECTION THE ON / OFF SWITCH FOR THE LIGHTS COULD NOT BE LOCATED NOR COULD IT BE VERIFIED THAT THEY ARE RUNNING THROUGH A GFCI CIRCUIT PER CODE.

NEC 680.23 Underwater Luminaires.
(A) General.

(2) Transformers. Transformers for underwater luminaires shall be an isolated winding type with a grounded metal barrier between the primary and secondary windings, and shall be listed for the purpose.
(3) GFCI Protection. Branch circuits supplying underwater luminaires that operate at more than 15V shall be GFCI protected. Figure 680-15 un680-15 680-23A3.cdr
(4) Voltage Limitation. Listed underwater luminaires shall not operate on circuits over 150V.
(5) Wall-Mounted Luminaires. Listed underwater luminaires shall be installed so that the top of the luminaire lens is at least 18 in. below the normal water level.
Author’s Comment: The 18 in. requirement is to reduce the likelihood that a person hanging over the side will have their chest cavity in line with the luminaire.

Spa Light Condition: Damaged (Water Present - Light Can Replacement $475)$750

Spa Light #1 Spa Light #2
Spa Light Notes
Spa Light Additional Notes

NOTE: OWNER INDICATED THAT THE POOL LIGHT / SPA LIGHT DO NOT OPERATE. DURING THE INSPECTION THE ON / OFF SWITCH FOR THE LIGHTS COULD NOT BE LOCATED NOR COULD IT BE VERIFIED THAT THEY ARE RUNNING THROUGH A GFCI CIRCUIT PER CODE.

NEC 680.23 Underwater Luminaires.
(A) General.

(2) Transformers. Transformers for underwater luminaires shall be an isolated winding type with a grounded metal barrier between the primary and secondary windings, and shall be listed for the purpose.
(3) GFCI Protection. Branch circuits supplying underwater luminaires that operate at more than 15V shall be GFCI protected. Figure 680-15 un680-15 680-23A3.cdr
(4) Voltage Limitation. Listed underwater luminaires shall not operate on circuits over 150V.
(5) Wall-Mounted Luminaires. Listed underwater luminaires shall be installed so that the top of the luminaire lens is at least 18 in. below the normal water level.
Author’s Comment: The 18 in. requirement is to reduce the likelihood that a person hanging over the side will have their chest cavity in line with the luminaire.

Equipment Pad


Filter Condition: Poor (High Filter Pressure - Low Water Qaulity - Filter Internal Replacment $150+) $

Filter #1 Filter #2
Filter Brand Filter Model
CARTRIDGE
Filter Notes
Filter Additional Notes

Filter Pump Condition: Good$

Filter Pump #1 Filter Pump #2
Filter Pump Brand Filter Pump Model Horsepower
Pentair
Filter Pump Condition
Water leaking from the shaft seal, Water leaking from the return and/ or suction sides of pump connection(s).
Filter Pump Notes
Filter Pump Additional Notes
Filter Pump Additional Repairs

Booster Pump Condition: $

Booster Pump #1 Booster Pump #2
Booster Pump Brand Booster Pump Model Horsepower
Booster Pump Additional Notes

Spa Jet Pump Condition: N/A$

Spa Jet Pump #1 Spa Jet Pump #2
Spa Jet Brand Spa Jet Model Horsepower
Spa Jet Additional Notes

NOTE: SPA SHARES THE POOL FILTRATION PUMP. NO JET PUMP


Waterfall Pump Condition: N/A$

Waterfall Pump #1 Waterfall Pump #2
Waterfall Pump Brand Waterfall Pump Model Horsepower
Waterfall Pump Additional Notes

NOTE: WATERFALL OPERATES BY TURNING A MANUAL VALVE AT THE EQUIPMENT PAD.

Auxiliary Pump A Condition: N/A$

Auxiliary Pump A #1 Auxiliary Pump A #2
Auxiliary Pump A Brand Auxiliary Pump A Model Horsepower
Auxiliary Pump A Additional Notes

Auxiliary Pump B Condition: N/A $

Auxiliary B #1 Auxiliary B #2
Auxiliary Pump B Brand Auxiliary Pump B Model Horsepower
Auxiliary Pump B Additional Notes

Heater Condition: Good $

Heater #1 Heater #2
Heater Model Heater Brand
Sta-Rite
Heater Additional Notes

Equipment Control System


Board & Timer Condition: Fair$

Board/Timer #1 Board/Timer #2
GFCI Compliant
No - Older GFI standard, tests, and resets the pool and or spa light. Recommend upgrading to GFCI standard for safety ($125)
Board & Timer Additional Notes

NOTE: TIMER OPERATES THE POOL / SPA FILTER PUMP. THERE IS A BLANKED OFF J-BOX JUST BELOW THE TIMER THAT SHOULD BE INVESTIGATED. IT MAY POSSIBLY HAVE AN ELECTRICAL RELATIONSHIP WITH THE MISSING LIGHT SWITCHING (ON/OFF)

Auxiliary Timer Condition: N/A $

Auxiliary Timer #1 Auxiliary Timer #2
Auxiliary Timer Additional Notes

Salt Control Systems Condition: N/A$

Salt Control #1 Salt Control #2
Salt System Power Detect Salt Flow Detect Salt Presence Low Salt
Salt Control System Additional Notes

Valves & Fittings Condition: Poor$

Overall Details

NOTE: THE PIPING SHOULD BE RE-PAINTED AND ALL VALVES SHOULD BE SERVICED. AT THE TIME OF THE INSPECTION WATER WAS PRESENT ON THE EQUIPMENT PAD. IT COULD NOT BE DETERMINED AS TO THE SOURCE OF THE WATER. IT MAY BE A LEAK OR IT COULD HAVE BEEN WATER SPILLED DURING A RECENT CLEANING OF THE PUMP'S BASKET.


Due for maintenance, medium equipment pad, Required every 10-15 years, all valving must be opened, cleaned, lubricated, and re sealed to ensure longevity of equipment.
Yes, the equipment pad is UV protected by a UV protectant paint, recommend painting this pad to ensure long PVC piping life as well as certain equipment
Condition
N/A
Notes

NOTE: 120v LIGHTING WAS RUNNING OVERHEAD ABOVE THE POOL / SPA. THE LIGHT WAS RUNNING ON AN EXTENSION CORD AND PLUGGED INTO A GFCI DUPLEX RECEPTACLE BUT, THIS IS TYPE OF LIGHTING INSTALLATION IS NOT PER CODE AND POSES A RISK TO HEALTH AND SAFETY.

RECOMMENDATION; REMOVE THIS LIGHTING AND INSTALL A WEATHER-PROOF COVER ON THE DUPLEX RECEPTACLE BEFORE USING THE POOL.

Condition
N/A
Notes

THE OVERHEAD LIGHTING WAS RUNNING ON AN EXTENSION CORD AND PLUGGED INTO A GFCI DUPLEX RECEPTACLE

Condition
N/A
Notes
Condition
N/A
Notes
Condition
N/A
Notes

Estimated pool repair costs based on typical seasonal construction pricing.(seasonal pricing changes $7378Est. Totals


Edit
 

Comments are closed.



Looking for something?

Use the form below to search the site:

Still not finding what you're looking for? Drop a comment on a post or contact us so we can
take care of it!

Pool Questions ? Call Us!

Do you need some swimming pool assistance? Maybe just a few questions answered ? Well give us a call, we are only a phone call away.

Sometimes you just need a second, qualified opinion.

Office: (916) 467-8038

Mobile: (916) 905-5818

Sacramento Pool Inspections & Service

We provide Weekly Pool & Spa Service, Pool Inspections, Pool Repairs, & Pool Tile Cleaning around the Sacramento Area, CA and the surrounding communities.

Swimming Pool Inspections & Service | (916) 905-5818