Expert Level Pool Inspections
Print Friendly Edit

1324 Hawthorne Loop,, Roseville,, CA (1:00 PM - April 7, 2020)

Google Maps

Front Of House Pool Spa

Equipment Pad

Equipment #1 Equipment #2 Equipment #3 Equipment #4 Equipment #5

Safety Fencing Condition: N/A $

Safety Fence #1 Safety Fence #2
Style Location
Wrought Iron
Safety Fencing Notes
Safety Fencing Additional Notes

Pool Safety & Drowning Prevention:

As of 2018 California Building Code (CBC) for Swimming Pool Safety Barriers / Enclosures Per Health & Safety Code 115922(a), the swimming pool and/or spa shall be equipped with at least two of the following seven drowning prevention safety features. Please provide a second feature. Note that a fence along the property's perimeter is not listed.

1) an enclosure that meets the requirements of Section 115923 the swimming pool or spa from the private single-family home; and isolates

(2) removable mesh fencing that meets American Society for Testing and Materials (ASTM) Specifications F2286 standards in conjunction with a gate that is self-closing and self-latching and can accommodate a key lockable device;

(3) an approved safety pool cover, as defined in subdivision (d) of Section 115921;

(4) exit alarms on a private single-family home's doors that provide direct access to the swimming pool or spa (provided on drawings);

(5) a self-closing, self-latching device with a release mechanism placed no lower than 54" above the floor on the private single-family home's doors providing direct access to the swimming pool or spa;

(6) an alarm that, when placed in a swimming pool or spa, will sound upon detection of accidental or unauthorized entrance into the water. The alarm shall meet and be independently certified to the ASTM Standards F2208 "Standard Safety Specification of Residential Pool Alarms," which includes surface motion, pressure, sonar, laser, and infrared type alarms. A swimming protection alarm feature designed for individual use, including an alarm attached to a child that sounds when the child exceeds a certain distance or becomes submerged in water, is not a qualifying drowning prevention safety feature.

(7) other means of protection, if the degree of protection afforded is equal to or greater than that afforded by any of the features listed above and has been independently verified by an approved testing laboratory as meeting standards for those features established by the ASTM or the American society of Mechanical Engineers (ASME).

NOTE: THE CURRENT GATE AT THE FRONT / SIDE ENTRY DOES NOT MEET CURRENT CODE. ALTHOUGH, AT THE TIME OF THIS INSPECTION THE WROUGHT IRON GATE AT THE POOL DID SWING OUTWARD AND CLOSED.

Pool Surface Condition: Damaged (Needs Attention) $5500

Surface #1 Surface #2
Estimated Gallons Surface Type
10K - 15K Gallons Plaster
Dimensions Damaged Estimated Surface Age
' by ' 0-10% 1-12 Months
Pool Surface Notes
There are large areas of staining and discoloration, The pool surface has discoloration throughout due to improper water balance over time, Recommend re-surface as soon as possible
Pool Surface Additional Notes

Plaster and Chemical Attack:

Cementitious surface coatings are susceptible to chemically and pH aggressive swimming pool water or to any chemical that is capable of deteriorating the cementitious materials of a surface coating.

Swimming pool water that is not in Ideal Range of acceptable tolerance (or “balanced”) as in accordance with the ANSI/APSP Standards is considered to be detrimental to cementitious surface coatings.

Depending on the direction of the imbalance a coating can either be stained or etched. Often, both staining and etching are exhibited on the surface of a coating as the pool water fluctuates from one extreme to the other.

There are visible signs of salt crystallization, surface efflorescence, or cracks that are emitting efflorescence or salt deposits which are common to a coating in contact with a positive saturation index (+ LSI), or “scaling” condition.

If the water is capable of leaching cement compounds from within the surface coating, then that water is in a negative saturation index (LSI), or "aggressive" condition.

If care is not taken to ensure that the water of a swimming pool is kept in an Ideal Range that is considered by ANSI/APSP to be balanced, and further that a sufficient amount of carbonate alkalinity buffer is

constantly present, then the cementitious surface coating should be considered susceptible to damage from that water and deterioration may result.

Water-soluble salts, acids, or ions such as sulfates, chlorides, and carbonates, can be transported into a cementitious surface coating and react with the cementitious compounds. The resulting chemical reaction between the cementitious compounds and these salts, acids, or ions, in the presence of water, can cause deterioration to the coating. Acidic water aggressively attacks and dissolves cementitious surface materials.

Water that is low in hardness, or soft water, can cause leaching of certain compounds of the cement, especially calcium hydroxide.

For more information about the National Plastering Council's re-plastering recommendations please go to their website: https://www.npconline.org

Tile Condition: Good$2500

Tile #1 Tile #2
Water Line Tile Linear Footage Tile Water Level Tile Linear Footage
N/A N/A
Tile Type Calcium Build-Up Loose or missing tile?
N/A or none
Mastic Repair
Additional Mastic Repairs

SEE EXAMPLE PROVIDED OF 3.00" OVERFLOW

Additional Tile Notes

The tile product appeared to be in satisfactory shape overall although there was a gap separation between the top of the tile and the concrete decking on the opposite side of the house (far side). The "water stop" black plastic strip was dislodged as a result due to the concrete deck settling causing the pool's cantilever edge to lift. This is probably (opinion) caused due to the pool overfilling during peak storm periods and allowing water to seep under the deck at this location.

PROPOSED REMEDY; Remove decking and replace. Reinstall water stop material and provide an 3.00" Overflow discharge line at top of tile "high water level" that's then ran to the yard drainage system. This will keep the pool from overfilling during peak storm periods.

Water Quality Condition: Good $

Water Picture #1 Water Picture #2
pH Level Free Chlorine Total Chlorine Cyanuric Alkalinity Calcium
6.8 - 7.2 (Ideal) 2 - 5 (Ideal) 2 - 5 (Ideal) 50 - 100 (Ideal) 45 - 70 (Ideal) 250 - 400 (Ideal)
pH Level Details Free Chlorine Details Total Chlorine Details Cyanuric Acid Details Alkalinity Notes Calcium Notes
Algae present? Foliage found in water? Water loss present?
No
Additional Water Quality Notes

Skimmer & Main Drain Circulation: N/A $291

Drain #1 Drain #2 Skimmer #1 Skimmer #2
Water Flow Through Skimmer Water Flow Through Main Drain Skimmer Float Valve
N/A 1
Pool Skimmer QTY Spa Skimmer QTY Pool Main Drain QTY Spa Main Drain QTY
1 N/A 1 N/A
VGBA Compliant Drain Covers
No / 2x Could Not Determine / Recommend VGBA Compliant Cover ($176)
Skimmer & Main Drain Details
The first skimmer is in *working* condition however it is missing its *float valve* ($50), The first skimmer is in *working* condition however it is missing its skimmer *float valve o-ring* ($65)

Skimmer & Main Drain Additional Notes

Virginia Graeme Baker Pool and Spa Safety Act Information

On December 19, 2008 the Federal Virginia Graeme Baker Pool and Spa Safety Act (VGBA) became effective. The VGBA requires all pool drain covers manufactured or sold in the United States to comply with new entrapment standards. VGBA also requires owners of all new and existing public swimming pool and spa suction outlet systems to install safety equipment, including ASME/ANSI A112.19.8 certified suction outlets and covers, designed to prevent entrapment.

Currently the pool’s drain cover devices do not meet the safety requirements and should be replaced when the pool is replastered.

Bottom Cleaner Condition: Damaged, some major parts need to be replaced ($205) $205

Cleaner #1 Cleaner #2
Bottom Cleaner Brand Bottom Cleaner Model
Polaris
Bottom Cleaner Additional Notes

THE BOTTOM CLEANER WAS OPERATION BUT, WAS OPERATING VERY SLOW AND INCONSISTENTLY. RECOMMEND REPAIRS

Bottom Cleaner Additional Repairs

Auto-Fill Condition: $

Autofill #1 Autofill #2
Pool Auto-Fill Spa Auto-Fill Auto-Fill Style Fill Speed
No Manual Medium
Auto-Fill Additional Notes

Pool Light Condition: $

Pool Light #1 Pool Light #2
Pool Light Type Distance From Electrical
Pool Light Notes

NEC 680.23 Underwater Luminaires.
(A) General.

(2) Transformers. Transformers for underwater luminaires shall be an isolated winding type with a grounded metal barrier between the primary and secondary windings, and shall be listed for the purpose.
(3) GFCI Protection. Branch circuits supplying underwater luminaires that operate at more than 15V shall be GFCI protected. Figure 680-15 un680-15 680-23A3.cdr
(4) Voltage Limitation. Listed underwater luminaires shall not operate on circuits over 150V.
(5) Wall-Mounted Luminaires. Listed underwater luminaires shall be installed so that the top of the luminaire lens is at least 18 in. below the normal water level.
Author’s Comment: The 18 in. requirement is to reduce the likelihood that a person hanging over the side will have their chest cavity in line with the luminaire.

NOTE: THE POOL LIGHT COULD NOT BE TESTED AS THE ON / OFF SWITCH APPEARED TO BE LOCATED INSIDE THE HOME AND WE WERE ASKED NOT TO DISTURB THE RESIDENT.

Spa Light Condition: $

Spa Light #1 Spa Light #2
Spa Light Notes
Spa Light Additional Notes

Equipment Pad


Filter Condition: Great $

Filter #1 Filter #2
Filter Brand Filter Model
Sta-Rite
Filter Notes
Low Filter Pressure - Indicating Low Flow or Newly Installed Filter Element
Filter Additional Notes

Filter Pump Condition: Good$

Filter Pump #1 Filter Pump #2
Filter Pump Brand Filter Pump Model Horsepower
Sta-Rite
Filter Pump Condition
Filter Pump Notes
Good, the filter pump is in good working condition; The motor is warm or slightly hot, some air in the pump basket, motor is hot to the touch, recommend upgrading the status of this pump by; cleaning, lubricating, and resealing all pump suction and return side fitting o-rings.
Filter Pump Additional Notes
Filter Pump Additional Repairs

Booster Pump Condition: Fair (Replacement recommended in 6 months - 5 years $455)$455

Booster Pump #1 Booster Pump #2
Booster Pump Brand Booster Pump Model Horsepower
Sta-Rite ≤ 0.99HP
Booster Pump Additional Notes

THE CLEANER BOOSTER PUMP APPEARED TO HAVE A SMALL LEAK.

Spa Jet Pump Condition: N/A$

Spa Jet Pump #1 Spa Jet Pump #2
Spa Jet Brand Spa Jet Model Horsepower
Spa Jet Additional Notes

Waterfall Pump Condition: N/A$

Waterfall Pump #1 Waterfall Pump #2
Waterfall Pump Brand Waterfall Pump Model Horsepower
Waterfall Pump Additional Notes

Auxiliary Pump A Condition: N/A$

Auxiliary Pump A #1 Auxiliary Pump A #2
Auxiliary Pump A Brand Auxiliary Pump A Model Horsepower
Auxiliary Pump A Additional Notes

Auxiliary Pump B Condition: N/A $

Auxiliary B #1 Auxiliary B #2
Auxiliary Pump B Brand Auxiliary Pump B Model Horsepower
Auxiliary Pump B Additional Notes

Heater Condition: N/A $

Heater #1 Heater #2
Heater Model Heater Brand
Heater Additional Notes

Equipment Control System


Board & Timer Condition: Fair$

Board/Timer #1 Board/Timer #2
GFCI Compliant
Board & Timer Additional Notes

Auxiliary Timer Condition: N/A $

Auxiliary Timer #1 Auxiliary Timer #2
Auxiliary Timer Additional Notes

Salt Control Systems Condition: N/A$

Salt Control #1 Salt Control #2
Salt System Power Detect Salt Flow Detect Salt Presence Low Salt
Salt Control System Additional Notes

Valves & Fittings Condition: N/A$

Overall Details

THERE IS A GFCI DUPLEX RECEPTACLE LOCATED AT THE EQUIPMENT TIMER BOX. IT APPEARS THAT THIS MAY BE CONNECTED TO THE POOL LIGHTING CIRCUIT BUT, THIS COULD NOT BE CONFIRMED AT THE TIME OF THE INSPECTION. IT IS OUR RECOMMENDATION THAT CONFIRMATION IS MADE THAT THE POOL LIGHTING CIRCUIT IS IN FACT RAN THROUGH A GFCI CIRCUIT BY A LICENSED ELECTRICIAN PRIOR TO USING THE POOL.



Condition
N/A
Notes

POOL LIGHT DECK BOX LOCATION. VERIFY THAT THIS IS RUNNING THROUGH A GFCI CIRCUIT.

Condition
N/A
Notes

THERE IS A DUPLEX RECEPTACLE LOCATED IN THE CORNER OF THE FENCING ON THE FAR SIDE OF THE POOL OPPOSITE THE HOUSE. HAVE A LICENSED ELECTRICIAN VERIFY THAT THIS IS IN FACT CONNECTED TO A GFCI CIRCUIT PER NEC-680 CODE REQUIREMENTS.

Condition
N/A
Notes
Condition
N/A
Notes
Condition
N/A
Notes

Estimated pool repair costs based on typical seasonal construction pricing.(seasonal pricing changes $8951Est. Totals


Edit
 

Comments are closed.



Looking for something?

Use the form below to search the site:

Still not finding what you're looking for? Drop a comment on a post or contact us so we can
take care of it!

Pool Questions ? Call Us!

Do you need some swimming pool assistance? Maybe just a few questions answered ? Well give us a call, we are only a phone call away.

Sometimes you just need a second, qualified opinion.

Office: (916) 467-8038

Mobile: (916) 905-5818

Sacramento Pool Inspections & Service

We provide Weekly Pool & Spa Service, Pool Inspections, Pool Repairs, & Pool Tile Cleaning around the Sacramento Area, CA and the surrounding communities.

Swimming Pool Inspections & Service | (916) 905-5818