Expert Level Pool Inspections
Print Friendly Edit

11290 Watson Dr.,, Moorpark,, CA (3:00 PM - February 25, 2020)

Google Maps

Front Of House Pool Spa

Equipment Pad

Equipment #1 Equipment #2 Equipment #3 Equipment #4 Equipment #5

Safety Fencing Condition: Non-Code Compliant $0

Safety Fence #1 Safety Fence #2
Style Location
Combination of Masonry Walls & W.I. Side of home, $3,500-Estimated Retail Construction Value (ERCV)
Safety Fencing Notes
The fencing does not meet safety standards
Safety Fencing Additional Notes

Pool Safety & Drowning Prevention:

As of 2018 California Building Code (CBC) for Swimming Pool Safety Barriers / Enclosures Per Health & Safety Code 115922(a), the swimming pool and/or spa shall be equipped with at least two of the following seven drowning prevention safety features. Please provide a second feature. Note that a fence along the property's perimeter is not listed.

1) an enclosure that meets the requirements of Section 115923 the swimming pool or spa from the private single-family home; and isolates

(2) removable mesh fencing that meets American Society for Testing and Materials (ASTM) Specifications F2286 standards in conjunction with a gate that is self-closing and self-latching and can accommodate a key lockable device;

(3) an approved safety pool cover, as defined in subdivision (d) of Section 115921;

(4) exit alarms on a private single-family home's doors that provide direct access to the swimming pool or spa (provided on drawings);

(5) a self-closing, self-latching device with a release mechanism placed no lower than 54" above the floor on the private single-family home's doors providing direct access to the swimming pool or spa;

(6) an alarm that, when placed in a swimming pool or spa, will sound upon detection of accidental or unauthorized entrance into the water. The alarm shall meet and be independently certified to the ASTM Standards F2208 "Standard Safety Specification of Residential Pool Alarms," which includes surface motion, pressure, sonar, laser, and infrared type alarms. A swimming protection alarm feature designed for individual use, including an alarm attached to a child that sounds when the child exceeds a certain distance or becomes submerged in water, is not a qualifying drowning prevention safety feature.

(7) other means of protection, if the degree of protection afforded is equal to or greater than that afforded by any of the features listed above and has been independently verified by an approved testing laboratory as meeting standards for those features established by the ASTM or the American society of Mechanical Engineers (ASME).

NOTE: THE CURRENT GATES / ENTRY DOORS DO NOT MEET CURRENT CODE.

TWO DEVICES I.E.; "DROWNING PREVENTION SAFETY FEATURES" WERE NOT OBSERVED.

Pool Surface Condition: Damaged (Needs Attention) $2500

Surface #1 Surface #2
Estimated Gallons Surface Type
>25K Gallons $2,500-Estimated Retail Construction Value (ERCV)
Dimensions Damaged Estimated Surface Age
32' by 45' 0-10% 12-48 Months
Pool Surface Notes
The surface is uniform and smooth with little or no discoloration found, The pool surface appears to have no pitting or any loose surfaces present
Pool Surface Additional Notes

The spa step appears to have some large cracks that have been repaired previously.

There are no voids in the grout at the tile at the beach entry beyond normal wear.

A 24 hour water holding test was performed for the main body of the pool and it was determined to NOT be loosing water BEYOND a rate that exceeds the seasonal evaporate rate, according to the local CIMIS weather station.

The upper pool has some faux rockery cracking that may have water loss issues possible.

Plaster and Chemical Attack:

Cementitious surface coatings are susceptible to chemically and pH aggressive swimming pool water or to any chemical that is capable of deteriorating the cementitious materials of a surface coating.

Swimming pool water that is not in Ideal Range of acceptable tolerance (or “balanced”) as in accordance with the ANSI/APSP Standards is considered to be detrimental to cementitious surface coatings.

Depending on the direction of the imbalance a coating can either be stained or etched. Often, both staining and etching are exhibited on the surface of a coating as the pool water fluctuates from one extreme to the other.

There are visible signs of salt crystallization, surface efflorescence, or cracks that are emitting efflorescence or salt deposits which are common to a coating in contact with a positive saturation index (+ LSI), or “scaling” condition.

If the water is capable of leaching cement compounds from within the surface coating, then that water is in a negative saturation index (LSI), or "aggressive" condition.

If care is not taken to ensure that the water of a swimming pool is kept in an Ideal Range that is considered by ANSI/APSP to be balanced, and further that a sufficient amount of carbonate alkalinity buffer is constantly present, then the cementitious surface coating should be considered susceptible to damage from that water and deterioration may result.

Water-soluble salts, acids, or ions such as sulfates, chlorides, and carbonates, can be transported into a cementitious surface coating and react with the cementitious compounds. The resulting chemical reaction between the cementitious compounds and these salts, acids, or ions, in the presence of water, can cause deterioration to the coating. Acidic water aggressively attacks and dissolves cementitious surface materials.

Water that is low in hardness, or soft water, can cause leaching of certain compounds of the cement, especially calcium hydroxide.

For more information about the National Plastering Council's re-plastering recommendations please go to their website: https://www.npconline.org

Tile Condition: N/A$650

Tile #1 Tile #2
Water Line Tile Linear Footage Tile Water Level Tile Linear Footage
Less than 150 Linear Feet High
Tile Type Calcium Build-Up Loose or missing tile?
N/A Heavy Build Up ($650)
Mastic Repair
Additional Mastic Repairs

There is a scum line at the water level surface on the pebble, faux rockery and beach entry tile.

Additional Tile Notes

There isn't any waterline tile. The pool's interior pebble finish acts as the waterline tile. We recommend cleaning the scum line.

Water Quality Condition: Good $

Water Picture #1 Water Picture #2
pH Level Free Chlorine Total Chlorine Cyanuric Alkalinity Calcium
6.8 - 7.2 (Ideal) 50 - 100 (Ideal) 45 - 70 (Ideal) 250 - 400 (Ideal)
pH Level Details Free Chlorine Details Total Chlorine Details Cyanuric Acid Details Alkalinity Notes Calcium Notes
Algae present? Foliage found in water? Water loss present?
No
Additional Water Quality Notes

Skimmer & Main Drain Circulation: Good $440

Drain #1 Drain #2 Skimmer #1 Skimmer #2
Water Flow Through Skimmer Water Flow Through Main Drain Skimmer Float Valve
Good 1
Pool Skimmer QTY Spa Skimmer QTY Pool Main Drain QTY Spa Main Drain QTY
1 N/A 2 2
VGBA Compliant Drain Covers
No / 5x Could Not Determine / Recommend VGBA Compliant Cover ($88)
Skimmer & Main Drain Details
The first skimmer is in great working condition with a like new working skimmer float weir and an in tact, in place, like new skimmer float valve and float valve seal present

Skimmer & Main Drain Additional Notes

Virginia Graeme Baker Pool and Spa Safety Act Information

On December 19, 2008 the Federal Virginia Graeme Baker Pool and Spa Safety Act (VGBA) became effective. The VGBA requires all pool drain covers manufactured or sold in the United States to comply with new entrapment standards. VGBA also requires owners of all new and existing public swimming pool and spa suction outlet systems to install safety equipment, including ASME/ANSI A112.19.8 certified suction outlets and covers, designed to prevent entrapment.

Currently the pool’s drain cover devices do not meet the safety requirements and should be replaced when the pool is replastered.

Bottom Cleaner Condition: Fair, minimal parts needed for tune-up ($105) $105

Cleaner #1 Cleaner #2
Bottom Cleaner Brand Bottom Cleaner Model
"The Pool Cleaner"
Bottom Cleaner Additional Notes

Suction side style cleaner

Bottom Cleaner Additional Repairs

Auto-Fill Condition: $

Autofill #1 Autofill #2
Pool Auto-Fill Spa Auto-Fill Auto-Fill Style Fill Speed
No No Manual Slow
Auto-Fill Additional Notes

The pool appears to be filled by a garden hose, as it was noticed that at the time of this inspection a hose was left out on the pool deck.

Also, during the 24-hour water level test the equipment was left in a non-operation condition. Upon returning to check the water level the spa jets were on indicating that someone may have interfered with gaining accurate testing results.

If there are concerns with this, we recommend re-testing and informing the resident to leave all equipment in the non-operation mode while testing.

Pool Light Condition: $

Pool Light #1 Pool Light #2
Pool Light Type Distance From Electrical
Pool Light Notes

The GFCI Duplex Receptacle was tripped and will not reset. This electrical source is supposed to provide power to the pool and spa lights but was found to be non-operational.

We recommend hiring a Licensed Electrical Contractor to investigate and repair this issue before using the pool, spa and or water features.

NEC 680.23 Underwater Luminaires.
(A) General.

(2) Transformers. Transformers for underwater luminaires shall be an isolated winding type with a grounded metal barrier between the primary and secondary windings, and shall be listed for the purpose.
(3) GFCI Protection. Branch circuits supplying underwater luminaires that operate at more than 15V shall be GFCI protected. Figure 680-15 un680-15 680-23A3.cdr
(4) Voltage Limitation. Listed underwater luminaires shall not operate on circuits over 150V.
(5) Wall-Mounted Luminaires. Listed underwater luminaires shall be installed so that the top of the luminaire lens is at least 18 in. below the normal water level.
Author’s Comment: The 18 in. requirement is to reduce the likelihood that a person hanging over the side will have their chest cavity in line with the luminaire.

Spa Light Condition: $

Spa Light #1 Spa Light #2
Spa Light Notes
Spa Light Additional Notes

Equipment Pad


Filter Condition: Fair (Normal to High Filter Pressure - Filter Cleaning Treatment Recommended $55) $

Filter #1 Filter #2
Filter Brand Filter Model
Jandy, 148-SF & 160-SF D.E. Filters Jandy Model # NSE-D.E. Filter
Filter Notes
Normal to High Filter Pressure - Indicating a filter cleaning ($85) is necessary to identify filter element quality of life, if elements were recently cleaned this is indicating element replacement is needed in the next 1 - 24 months ($150-450)
Filter Additional Notes

Filter Pump Condition: $

Filter Pump #1 Filter Pump #2
Filter Pump Brand Filter Pump Model Horsepower
Jandy Jandy E Series Variable Speed Variable Speed 1.5 - 3.1hp
Filter Pump Condition
Filter Pump Notes
Filter Pump Additional Notes
Filter Pump Additional Repairs

Booster Pump Condition: $

Booster Pump #1 Booster Pump #2
Booster Pump Brand Booster Pump Model Horsepower
Suction Side Cleaner
Booster Pump Additional Notes

Spa Jet Pump Condition: N/A$

Spa Jet Pump #1 Spa Jet Pump #2
Spa Jet Brand Spa Jet Model Horsepower
Spa Jet Additional Notes

There are two (2) air blower and both are operational.


Waterfall Pump Condition: N/A$750

Waterfall Pump #1 Waterfall Pump #2
Waterfall Pump Brand Waterfall Pump Model Horsepower
Jandy Stealth ≥ 2.50HP
Waterfall Pump Additional Notes

Waterfall pump seal plate is leaking.

Auxiliary Pump A Condition: Good$850

Auxiliary Pump A #1 Auxiliary Pump A #2
Auxiliary Pump A Brand Auxiliary Pump A Model Horsepower
Jandy Stealth ≥ 2.50HP
Auxiliary Pump A Additional Notes

All plumbing needs to be re-painted and valves re-lubed and serviced

Auxiliary Pump B Condition: Good $

Auxiliary B #1 Auxiliary B #2
Auxiliary Pump B Brand Auxiliary Pump B Model Horsepower
Jandy Stealth ≥ 2.50HP
Auxiliary Pump B Additional Notes

Heater Condition: N/A $450

Heater #1 Heater #2
Heater Model Heater Brand
Pentair, Jandy Pentair Master Temp and Jandy HiEQR
Heater Additional Notes

Both Heaters are operational but, they do not have a "Drip Leg" installed per CPC code requirements.

Equipment Control System


Board & Timer Condition: Fair$

Board/Timer #1 Board/Timer #2
GFCI Compliant
GFCI Duplex Receptacle is non-op
Board & Timer Additional Notes

The Controller is a Jandy Aqualink system and all relays are functioning in manual mode at the panel.

Auxiliary Timer Condition: N/A $

Auxiliary Timer #1 Auxiliary Timer #2
Auxiliary Timer Additional Notes

Salt Control Systems Condition: Poor$

Salt Control #1 Salt Control #2
Salt System Power Detect Salt Flow Detect Salt Presence Low Salt
Yes Yes Yes Yes
Salt Control System Additional Notes

The Jandy system is still plumbed but no cord connected and appears to be not operational. The Hayward Gold-line is connected to power but indicates 1800 and check cell. This usually indicates a low salt content in the pool.

Valves & Fittings Condition: Good$

Overall Details

Due for maintenance, small equipment pad, Required every 10-15 years, all valving must be opened, cleaned, lubricated, and re sealed to ensure longevity of equipment.
No, the equipment pad is not UV protected by a UV protectant paint, recommend painting this pad to ensure long PVC piping life as well as certain equipment
Condition
N/A
Notes
Condition
N/A
Notes
Condition
N/A
Notes
Condition
N/A
Notes
Condition
N/A
Notes

Estimated pool repair costs based on typical seasonal construction pricing.(seasonal pricing changes $5745Est. Totals


Edit
 

Comments are closed.



Looking for something?

Use the form below to search the site:

Still not finding what you're looking for? Drop a comment on a post or contact us so we can
take care of it!

Pool Questions ? Call Us!

Do you need some swimming pool assistance? Maybe just a few questions answered ? Well give us a call, we are only a phone call away.

Sometimes you just need a second, qualified opinion.

Office: (916) 467-8038

Mobile: (916) 905-5818

Sacramento Pool Inspections & Service

We provide Weekly Pool & Spa Service, Pool Inspections, Pool Repairs, & Pool Tile Cleaning around the Sacramento Area, CA and the surrounding communities.

Swimming Pool Inspections & Service | (916) 905-5818