Expert Level Pool Inspections
Print Friendly Edit

105 Eagle Creek, Folsom,, CA (12:00 PM - January 20, 2020)

Google Maps

Front Of House Pool Spa

Equipment Pad

Equipment #1 Equipment #2 Equipment #3 Equipment #4 Equipment #5

Safety Fencing Condition: N/A $0

Safety Fence #1 Safety Fence #2
Style Location
Wrought Iron Side of home
Safety Fencing Notes
The safety fencing is in good working conditon, The fencing needs minor repair to self close and self latch, The access gate does not swing away from the pool, The fencing does not meet safety standards
Safety Fencing Additional Notes

Pool Safety & Drowning Prevention:
As of 2018 California Building Code (CBC) for Swimming Pool Safety Barriers / Enclosures Per Health & Safety Code 115922(a), the swimming pool and/or spa shall be equipped with at least two of the following seven drowning prevention safety features. Please provide a second feature. Note that a fence along the property's perimeter is not listed.
1) an enclosure that meets the requirements of Section 115923 the swimming pool or spa from the private single-family home; and isolates
(2) removable mesh fencing that meets American Society for Testing and Materials (ASTM) Specifications F2286 standards in conjunction with a gate that is self-closing and self-latching and can accommodate a key lockable device;
(3) an approved safety pool cover, as defined in subdivision (d) of Section 115921;
(4) exit alarms on a private single-family home's doors that provide direct access to the swimming pool or spa (provided on drawings);
(5) a self-closing, self-latching device with a release mechanism placed no lower than 54" above the floor on the private single-family home's doors providing direct access to the swimming pool or spa;
(6) an alarm that, when placed in a swimming pool or spa, will sound upon detection of accidental or unauthorized entrance into the water. The alarm shall meet and be independently certified to the ASTM Standards F2208 "Standard Safety Specification of Residential Pool Alarms," which includes surface motion, pressure, sonar, laser, and infrared type alarms. A swimming protection alarm feature designed for individual use, including an alarm attached to a child that sounds when the child exceeds a certain distance or becomes submerged in water, is not a qualifying drowning prevention safety feature.
(7) other means of protection, if the degree of protection afforded is equal to or greater than that afforded by any of the features listed above and has been independently verified by an approved testing laboratory as meeting standards for those features established by the ASTM or the American society of Mechanical Engineers (ASME).

NOTE: THE CURRENT GATE AT THE FRONT / SIDE ENTRY DOES NOT MEET CURRENT CODE.

TWO DEVICES I.E.; "DROWNING PREVENTION SAFETY FEATURES" WERE NOT OBSERVED.

Pool Surface Condition: Fair (1-72 Months) $

Surface #1 Surface #2
Estimated Gallons Surface Type
<10K Gallons Painted or Epoxy Coating
Dimensions Damaged Estimated Surface Age
5' by 7' 10-50% 12-48 Months
Pool Surface Notes
There are some small areas of staining or discoloration, The surface is slightly abrasive and not as smooth or as new and will allow more organic matter to grow as a result of the slightly abrasive surface
Pool Surface Additional Notes

Plaster and Chemical Attack:
Cementitious surface coatings are susceptible to chemically and pH aggressive swimming pool water or to any chemical that is capable of deteriorating the cementitious materials of a surface coating.
Swimming pool water that is not in Ideal Range of acceptable tolerance (or “balanced”) as in accordance with the ANSI/APSP Standards is considered to be detrimental to cementitious surface coatings.
Depending on the direction of the imbalance a coating can either be stained or etched. Often, both staining and etching are exhibited on the surface of a coating as the pool water fluctuates from one extreme to the other.
There are visible signs of salt crystallization, surface efflorescence, or cracks that are emitting efflorescence or salt deposits which are common to a coating in contact with a positive saturation index (+ LSI), or “scaling” condition.
If the water is capable of leaching cement compounds from within the surface coating, then that water is in a negative saturation index (LSI), or "aggressive" condition.
If care is not taken to ensure that the water of a swimming pool is kept in an Ideal Range that is considered by ANSI/APSP to be balanced, and further that a sufficient amount of carbonate alkalinity buffer is constantly present, then the cementitious surface coating should be considered susceptible to damage from that water and deterioration may result.
Water-soluble salts, acids, or ions such as sulfates, chlorides, and carbonates, can be transported into a cementitious surface coating and react with the cementitious compounds. The resulting chemical reaction between the cementitious compounds and these salts, acids, or ions, in the presence of water, can cause deterioration to the coating. Acidic water aggressively attacks and dissolves cementitious surface materials.
Water that is low in hardness, or soft water, can cause leaching of certain compounds of the cement, especially calcium hydroxide.
For more information about the National Plastering Council's re-plastering recommendations please go to their website: https://www.npconline.org

Tile Condition: Good$550

Tile #1 Tile #2
Water Line Tile Linear Footage Tile Water Level Tile Linear Footage
Less than 80 Linear Feet Ideal
Tile Type Calcium Build-Up Loose or missing tile?
Tile appears to be a clay base Mexican sautio N/A or none No missing tiles or N/A
Mastic Repair
Additional Mastic Repairs

The spa has only a single main drain suction source device and the image in this category does not represent a surface skimmer but, it appears to be an overflow that may connect to the yard drainage system.

Also, there appears to be cracking in the raised wall behind the spa and some of pipes that are encapsulated inside the wall are exposed and unprotected from UV exposure by painting, on the back side.

Additional Tile Notes

This type of tile can absorb water and isn't usually seen as a pool or spa water line tile (opinion). The grout appears to be in need cleaning and possibly some re-grouting afterwards.

Water Quality Condition: Good $295

Water Picture #1 Water Picture #2
pH Level Free Chlorine Total Chlorine Cyanuric Alkalinity Calcium
6.8 - 7.2 (Ideal) 2 - 5 (Ideal) 2 - 5 (Ideal) 50 - 100 (Ideal) 45 - 70 (Ideal) 250 - 400 (Ideal)
pH Level Details Free Chlorine Details Total Chlorine Details Cyanuric Acid Details Alkalinity Notes Calcium Notes
Algae present? Foliage found in water? Water loss present?
Filter Cleaning and Filter Treatment 1 - 10 days after treatments would help reduce and eliminate algae and organic debris ($125), A phosphate treatment ($85) will help reduce dissolved organics (100-1000ppb) by coagulating organics for 7-10 days allowing collection to occur on the filter. A filter cleaning is required after treatment. Yes - Recommend Phosphate Treatment
Additional Water Quality Notes

Skimmer & Main Drain Circulation: Good $

Drain #1 Drain #2 Skimmer #1 Skimmer #2
Water Flow Through Skimmer Water Flow Through Main Drain Skimmer Float Valve
Good N/A
Pool Skimmer QTY Spa Skimmer QTY Pool Main Drain QTY Spa Main Drain QTY
N/A N/A N/A 1
VGBA Compliant Drain Covers
Skimmer & Main Drain Details


Skimmer & Main Drain Additional Notes

Virginia Graeme Baker Pool and Spa Safety Act Information

On December 19, 2008 the Federal Virginia Graeme Baker Pool and Spa Safety Act (VGBA) became effective. The VGBA requires all pool drain covers manufactured or sold in the United States to comply with new entrapment standards. VGBA also requires owners of all new and existing public swimming pool and spa suction outlet systems to install safety equipment, including ASME/ANSI A112.19.8 certified suction outlets and covers, designed to prevent entrapment.

Currently the pool’s drain cover devices do not meet the safety requirements and should be replaced when the pool is replastered.

Bottom Cleaner Condition: $

Cleaner #1 Cleaner #2
Bottom Cleaner Brand Bottom Cleaner Model
Bottom Cleaner Additional Notes
Bottom Cleaner Additional Repairs

Auto-Fill Condition: Good ($10)$

Autofill #1 Autofill #2
Pool Auto-Fill Spa Auto-Fill Auto-Fill Style Fill Speed
Yes Manual Fast
Auto-Fill Additional Notes

Pool Light Condition: $

Pool Light #1 Pool Light #2
Pool Light Type Distance From Electrical
Pool Light Notes

Spa Light Condition: Fair$575

Spa Light #1 Spa Light #2
Spa Light Notes
Spa Light Additional Notes

NEC 680.23 Underwater Luminaires.

(A) General.

(2) Transformers. Transformers for underwater luminaires shall be an isolated winding type with a grounded metal barrier between the primary and secondary windings, and shall be listed for the purpose.

(3) GFCI Protection. Branch circuits supplying underwater luminaires that operate at more than 15V shall be GFCI protected. Figure 680-15 un680-15 680-23A3.cdr
(4) Voltage Limitation. Listed underwater luminaires shall not operate on circuits over 150V.

(5) Wall-Mounted Luminaires. Listed underwater luminaires shall be installed so that the top of the luminaire lens is at least 18 in. below the normal water level.

Comment: The 18 in. requirement is to reduce the likelihood that a person hanging over the side will have their chest cavity in line with the luminaire.

NOTE: The spa's light was not operational nor could the GFCI interface be tested. The Owner commented that the bulb was out. It is my recommendation that the spa not be used until the lighting issue is corrected and verified that the light is in fact ran through the GFCI power circuit protection per code.

NOTE: At the spa equipment pad area their is a Light Junction Box (LJB) that is approx. +18" above FC elevation and the spas approx. +18" above FC elevation. This is not allowed per NEC 680 regulations. The LJB should be +12" min. above the spa water's static level.

When replaceing / repaining the light the LJB should be raised up a min. of +36" form FC elevation.

Equipment Pad


Filter Condition: Poor (High Filter Pressure - Low Water Qaulity - Filter Internal Replacment $150+) $650

Filter #1 Filter #2
Filter Brand Filter Model
Pentair Pentair CC150 Clear & Clean Cartridge
Filter Notes
Filter Additional Notes

Filter is running at over 30 psi and this would normally indicate that a Filter Cleaning is in order. Additionally, the filter's plumbing extends over the Equipment Pad disabling the complete closure of the double gate to completely close.

Filter Pump Condition: Other$250

Filter Pump #1 Filter Pump #2
Filter Pump Brand Filter Pump Model Horsepower
3/4-HP @ 1.25 Service Factor 1.00HP - 1.25HP
Filter Pump Condition
Filter Pump Notes
Filter Pump Additional Notes

The pump appears to be leaking,. Due to wet weather conditions it could not be determined exactly where the leak is coming from.

Filter Pump Additional Repairs

Booster Pump Condition: $

Booster Pump #1 Booster Pump #2
Booster Pump Brand Booster Pump Model Horsepower
Booster Pump Additional Notes

Spa Jet Pump Condition: N/A$

Spa Jet Pump #1 Spa Jet Pump #2
Spa Jet Brand Spa Jet Model Horsepower
1.00HP - 1.25HP
Spa Jet Additional Notes

Spa jets operate in conjunction with the spa filtration mode.


Waterfall Pump Condition: N/A$

Waterfall Pump #1 Waterfall Pump #2
Waterfall Pump Brand Waterfall Pump Model Horsepower
Waterfall Pump Additional Notes

Auxiliary Pump A Condition: N/A$

Auxiliary Pump A #1 Auxiliary Pump A #2
Auxiliary Pump A Brand Auxiliary Pump A Model Horsepower
Auxiliary Pump A Additional Notes

Auxiliary Pump B Condition: N/A $

Auxiliary B #1 Auxiliary B #2
Auxiliary Pump B Brand Auxiliary Pump B Model Horsepower
Auxiliary Pump B Additional Notes

Heater Condition: Damaged (Needs Attention) $2500

Heater #1 Heater #2
Heater Model Heater Brand
Heater Additional Notes

The heater's gas connection is missing the "Drip Leg" which is required per California Plumbing Code (CPC). This should be corrected when repairing or replacing the heater.

NOTE: the heater is located under a second story window where CO2 can pose a health risk per CPC. An exhaust vent should route the heater's exhaust above the roof line per the Mfg.'s recoomendations.

Equipment Control System


Board & Timer Condition: Fair$2250

Board/Timer #1 Board/Timer #2
GFCI Compliant
GFI/GFCI/Light Breaker/Plug is not connected to any light, recommend service to repair and upgrade this issue for safety ($245)
Board & Timer Additional Notes

The timer device is a simple on and off programmable system. If wireless automation control is desired then this would need to be upgraded so that pumps and valves could turn automatically.

Auxiliary Timer Condition: N/A $

Auxiliary Timer #1 Auxiliary Timer #2
Auxiliary Timer Additional Notes

Salt Control Systems Condition: N/A$

Salt Control #1 Salt Control #2
Salt System Power Detect Salt Flow Detect Salt Presence Low Salt
Salt Control System Additional Notes

Valves & Fittings Condition: Poor$1100

Overall Details

The valves, pumps, filter, heater and piping needs attention. There isn't adequate space in which to service and inspect completely around all hardware and components. All bonding wire were connected per NEC but the equipment needs to possibly be set up on a stacked racking system in order to be provide for better accessibility.


Due for maintenance, small equipment pad, Required every 10-15 years, all valving must be opened, cleaned, lubricated, and re sealed to ensure longevity of equipment.
No, the equipment pad is not UV protected by a UV protectant paint, recommend painting this pad to ensure long PVC piping life as well as certain equipment
Condition
N/A
Notes
Condition
N/A
Notes
Condition
N/A
Notes
Condition
N/A
Notes
Condition
N/A
Notes

Estimated pool repair costs based on typical seasonal construction pricing.(seasonal pricing changes $8170Est. Totals


Edit
 

Comments are closed.



Looking for something?

Use the form below to search the site:

Still not finding what you're looking for? Drop a comment on a post or contact us so we can
take care of it!

Pool Questions ? Call Us!

Do you need some swimming pool assistance? Maybe just a few questions answered ? Well give us a call, we are only a phone call away.

Sometimes you just need a second, qualified opinion.

Office: (916) 467-8038

Mobile: (916) 905-5818

Sacramento Pool Inspections & Service

We provide Weekly Pool & Spa Service, Pool Inspections, Pool Repairs, & Pool Tile Cleaning around the Sacramento Area, CA and the surrounding communities.

Swimming Pool Inspections & Service | (916) 905-5818